- ページ 3

カーアラーム AME MM-2のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。AME MM-2 18 ページ。
AME MM-2 にも: ユーザーマニュアル (20 ページ)

AME MM-2 インストレーション・マニュアル
the beep until the indicator icon on the LCD screen is flashing two times to confirm the main unit code has been
programmed to the transceiver, otherwise the pager function will not work.
3. To exit the Code Learning switch the ignition off and wait for 15 seconds, a double siren beep will confirm that
Code Learning has exited. NOTE: If you want to move to the Function Programming switch the ignition back on
before the double siren beep.
WARNING!: When you press button 1 while programming the Two way Transceivers at the same time the main
unit code is being programmed to the transceiver memory for the pager function to enable, so wait for the indicator
icon on LCD panel to flash a double flash to confirm the main unit code is learnt by the transceiver. Be noted the
pager function on the Transceiver will only be available with the latest learned alarm unit. If you program the
transceiver to different alarm unit the previous unit code will be removed from the transceiver memory.

Function programming.

1. Follow through with transmitter programming and turn the ignition back on (before the double siren beep in the
above item 3!).
2. Press button 1 on the transmitter 15 times. The alarm system will provide an audible confirmation on each
pressing the button. When you are pressing the button the 15th time the siren will emit two long beeps
followed by two short beeps.
3. Press buttons 1 and 2 together to enter the Installer Software Switch Table.
4. Enter the number of the function that you want to adjust by pressing button one on the transmitter to increase
the number of function or by pressing button 2 to reduce the number of function.
5. Each time the transmitter button is pressed; the siren will beep to indicate the switch that is selected. The
following siren beep sequence will be used: Switch 1 = One short beep, Switch 2 = Two short beeps, ... Switch
5 = One long beep, Switch 6 = One long beep and one short beep, ... and so on.
6. Press both buttons 1 and 2 to toggle the status of the dual state functions from option 1 to option 2 and from
option 2 to option 1. If the Software switch includes more than two states, follow the instruction within a
respective line of the table below.
7. If option 1 is selected, the LED will be on. If option 2 is selected, the LED will be off.
8. Turn off the ignition and wait 15 seconds. The system will give a double beep to confirm it has exited software
switch adjustment.
Installation manual
AME MM 2 Car Alarm System
2