- ページ 9
モニター Acer 41AS551V AC511のPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Acer 41AS551V AC511 50 ページ。
All manuals and user guides at all-guides.com
D. The adjustment of 6500°K white Balance, May follow step A ~ C , with the x=313 ± 10, y=329 ± 10.
E. Full white luminance:
(a) Set mode 2 640×480 Fh: 31.5KHz full white pattern.
(b) Image Size : H:260±4mm V:195±4mm.
(c) Brightness set to raster just cut off and set the contrast to max.
(d) Adjust VR701 to the luminance at 100 ± 5cd/m².
4. Focus Adjustment:
A. Set mode 2 640×480 Fh: 53.8KHz with character full page.
B. Adjust brightness to center and contrast to max.
C. Then adjust focus VR to a fine vertical and horizontal line.
5. Purity Adjustment
A. Be sure that the display is not being exposed to any external magnetic fields.
B. Ensure that the spacing between the Purity, Convergence, Magnet, (PCM), assembly and the CRT stem is
29mm. (See below diagram)
C. Produce a complete, red pattern on the display. Adjust the purity magnet rings on the PCM assembly to
obtain a complete field of the color red. This is done by moving the two tabs in such a manner that they
advance in an opposite direction but at the same time to obtain the same angle between the two tabs,
which should be approximately 180'.
D. Check the complete blue and complete green patterns to observe their respective color purity. Make minor
adjustments if needed.
RELATIVE PLACEMENT OF TYPICAL COMPONENTS
6. Convergence adjustment
A. Produce a magenta crosshatch on the display.
B. Adjust the focus for the best overall focus on the display.
Also adjust the brightness to the desired condition.
C. Vertical red and blue lines are converged by varying the angle between the two tabs of the 4 pole magnets
on the PCM assembly. (See above diagrams)
D. Horizontal red and blue lines are converged by varying the two tabs together, keeping the angle between
them constant.
E. Produce a white crosshatch pattern on the display.
F. Vertical green and magenta lines are converged by varying the angle between the two tabs of the 6-pole
magnets.
G. Horizontal green and magenta lines are converged by varying the two tabs together, keeping the angle
between them constant.
Purity Magnets
6-pole Convergence Magnets
4-pole Convergence Magnets
Deflection Yoke
8