エアコン Coast-Air CEW061BSのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Coast-Air CEW061BS 16 ページ。

Coast-Air CEW061BS 据付・取扱説明書
Installation and Operation Instruction Manual
INSTALLATION INSTRUCTIONS
INSTALL WEATHER STRIPPING (only
7
be applicable to Energy star models )
In order to minimize air leaks between the room air
conditioner and the window opening, trim the weather
stripping with the proper length, peel off the protective
backing and plug any gaps if needed (Fig.14).
Fig.14
If AC is Blocked by Storm Window
Add wood as shown in Fig.15, or remove storm
window before air conditioner is installed.
If Storm Window Frame must remain, be sure the
drain holes or slots are not caulked or painted shut.
Accumulated Rain Water or Condensation must be
allowed to drain out.
Removing AC From Window
Turn AC off, and disconnect power cord.
Remove sash seal from between windows, and
unscrew safety sash lock.
Remove screws installed through frame and frame-
lock.
Remove the R1 Panel and close (slide) side panels
into frame.
Keeping a firm grip on air conditioner, raise sash
and carefully remove.
Be careful not to spill any remaining water while
lifting unit from window. Store parts WITH air
conditioner.
Storm window
frame or other
obstruction.
8
8
6,000 - 12,000
SASH
1-1/2"min
Board
thickness
(38 mm)
as required,
for proper
pitch to rear,
along entire
sill. Fasten
with nails or
screws.
Fig.15
www.coastair-ac.com