- ページ 2
計測機器 Aktakom ATE-9030のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Aktakom ATE-9030 9 ページ。 Sound level meter
Your purchase of this SOUND LEVEL METER with SD CARD DATA RECORDER marks a step forward for you into
the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure
will allow many years of use if proper operating techniques are developed. Please read the following instructions
carefully and always keep this manual within easy reach.
1. FEATURES
* Main functions are designed to meet IEC 61672 class 2.
* A & C weighting networks comply with standards.
* 0.5" standard microphone head.
* Time weighting (Fast & Slow) dynamic characteristic modes.
* Build External calibration VR.
* Auto range & Manual range selection.
* Available for external calibration adjustment.
* Condenser microphone for high accuracy & long-term stability.
* Memory function to store the Max. & Min. value.
* Hold and Peak Hold functions.
* Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder, sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available (set the sampling time to 0 second), during execute the manual datalogger function,
it can set the different position (location) No. (position 1 to position 99).
* Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take
away the SD card from the meter and plug in the SD card into the computer, it can download the all the measured
value with the time information (year/month/date/hour/minute/second) to the Excel directly, then user can make the
further data or graphic analysis by themselves.
* SD card capacity: 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA (1.5V) x 6 batteries or DC 9V adapter.
* RS-232/USB PC COMPUTER interface.
* Heavy duty & compact housing case.
2. SPECIFICATION
Circuit
Display
Measurement Range
Resolution
Function
Accuracy
(23 ± 5°C)
Frequency Weighting Network
Time weighting (Fast & Slow)
Data hold
Peak hold
Range selector
Frequency
Microphone type
Microphone size
Calibration VR
2
Custom one-chip of microprocessor LSI circuit
LCD size: 52×38mm. LCD with green backlight (ON/OFF)
30...130dB
0.1 dB
dB (A & C frequency weighting), Time weighting (Fast, Slow), Peak hold, Data hold, Record (Max.,
Min.).
Characteristics of "A" frequency weighting network meet IEC 61672 class 2.
Under 94dB input signal, the accuracy are:
31.5Hz ± 3.5dB
63Hz ± 2.5dB
125Hz ± 2.0dB
250Hz ± 1.9dB
500Hz ± 1.9dB
1kHz ± 1.4dB
2kHz ± 2.6dB
4kHz ± 3.6dB
8kHz ± 5.6dB
Remark: The above spec. are tested under the environment RF Field Strength less than 3 V/M &
frequency less than 30MHz only.
Characteristics of A & C.
A weighting:
The characteristic is simulated as «Human Ear Listing» response. Typical, if making the
environmental sound level measurement, always select to A weighting.
C weighting:
The characteristic is near the «FLAT» response. Typical, it is suitable for checking the noise of
machinery (Q.C.check) & knowing the sound pressure level of the tested equipment.
Fast – t= 200ms
* «Fast» range is simulated the human ear (Fast & Slow) response time weighting.
Slow – t = 500ms
* «Slow» range is easy to get the average values of vibration sound level.
To freeze the measurement value.
To keep the peak (max.) measurement value
Auto range: 30 to 130dB.
Manual range: 3 range, 30 to 80dB, 50 to 100dB, 80 to 130dB, 50dB on each step, with over &
under range indicating.
31.5 to 8,000Hz.
Electric condenser microphone.
Out size, 12.7mm DIA. (1/2 inch).
Build in external calibration VR, easy to calibrate on 94dB level by screw driver.
* Calibrated via external SOUND CALIBRATOR (SC-941, optional).
www.tmatlantic.com