- ページ 14

マルチメーター Aktakom AMM-1081のPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。Aktakom AMM-1081 20 ページ。 Smart multimeter

5)When the resistance value is less than 10 ohm, the
beeper sound will be generated, the Display will
show "

Diode measurement

1)Connect BLACK test lead into " COM " terminal ( 3-9,
Fig. 1 ).
2)Connect RED test lead into " Ω " terminal ( 3-8, Fig. 1 ).
3)Select the " Function switch " ( 3-7, Fig. 1 ) to
"
" position.
4)Power On the meter by pressing the " Power On button "
( 3-2, Fig. 1 ) once, the Display will show " SMART ", the
meter is under " Smart " mode for Diode measurement.
5)a. When connected with polarity as shown in Fig. 2, a
forward current flow is established and the approx.
Diode Forward Voltage (VF) value in volt will
appears on the display reading. If the diode under
test is defective, " .000 " or near " .000 " value
( short circuit ) or " OL " ( open circuit ) will be
displayed.
" indicator.
11
www.tmatlantic.com
Fig. 2