Reset of the PM value / air sensor:
After prolonged use of the air sensor, traces of particles will stick to the inductive head of the sensor, which may
cause the numerical PM display to be abnormal. Only perform a reset if such an abnormal display is likely to occur!
If you find that the numeric PM reading deviates greatly from the normal range, we recommend that you record it in
the following steps based on the numeric PM reading of the weather forecast in your city.
1. First blow hard into the "compartment" of the air sensor (front left of the device). Then open a window for 5
minutes and place the air purifier near the window (the air sensor will record the current environmental data
again).
2. Then press and hold the "Settings" icon until you hear a click. Now you are automatically in PM correction
mode.
3. Each time you press the "Settings" key now, the PM number of the device will increase by 2ug/m³. Each time
you press the "Auto" key, you decrease the numerical PM value by 2ug/m³.
4. If you have adjusted the numerical PM values in the display to the numerical PM values of the weather forecast
of your city (look it up on the Internet), please wait for 5 seconds and the value will be overwritten and saved.
7.) Setting the fan strength (air circulation)
Press the Fan Speed button
Level 1
Level 2
Level 3
8.) Timer
Press the Timer button
select a value between 0 - 12 hours by pressing repeatedly. After you have selected your desired value, wait for
approx. 5 seconds until you hear an acknowledgement tone and the display panel shows the current temperature
and humidity value again. Now the remaining run time is stored and the air purifier switches off automatically after
this time has elapsed.
The remaining runtime is displayed alternately with the current temperature and the humidity value. In addition, you
can also display the remaining runtime by briefly pressing the timer key.
To reset the remaining run time, simply press the timer key continuously for approx. 3 seconds until the
acknowledgement tone sounds. This switches off (zeroes) the remaining runtime and the air purifier operates in
continuous mode again.
9.) Night operation / night mode
Press the Fan Speed button
the unit jumps to an extremely quiet fan strength !
To cancel the night mode, simply press again in the key area of the touch panel display.
in succession for the desired setting. The device has three fan speeds:
= Weak fan strength (air circulation)
= Average fan strength (air circulation)
= Strong fan strength (air circulation)
for approx. 3 seconds until the zero (0) starts flashing in the display field. Now you can
permanently for approx. 3-5 seconds. This turns off the touch panel display and
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de