- ページ 8

調理器 American Range ARPC-18のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。American Range ARPC-18 20 ページ。 Pasta cooker

Owner's Manual
INSTALLATION - GAS UTILITY CONNECTIONS-STANDARDS AND CODES
!
WARNING
Qualified installation personnel, licensed and bonded, must be experienced in such work, familiar with all precautions required and
have complied with all requirements of state or local authorities having jurisdiction.
The ventilation of these units should be in accordance with local codes. In absence of local codes, refer to the national ventilation
code titled, Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial
Cooking Equipment, NFPA-96-Latest Edition.
The appliance is to be installed with a check valve in accordance with applicable federal, province and local codes.
GENERAL EXPORT INSTALLATIONS
Installation must conform to Local and National Standards. Local installation codes and/or requirements may vary. If you have any
questions regarding the proper installation or operation of your American Range Pasta Cooker please contact your local distributor.
If you do not have a local distributor, contact American Range Corporation at 1.888.753.9898 or visit us at www.americanrange.com.

GAS CONNECTION

Your appliance will give you peak performance when the gas supply line is of sufficient size to provide the correct gas flow. The gas
line must be installed to meet the local building codes or National Fuel Gas Code ANS Z223.1 and NFPA 54 (latest editions). In
Canada, install the appliance in accordance with CSA B149.1 or .2 and local codes. Gas line sizing requirements can be determined
by a qualified installation professional, your local gas company or by referring to the National Gas Fuel Code, Appendix C, Table C-4
(for natural gas) and Table C-16 (for propane). The gas line needs to be large enough to supply the necessary amount of fuel to all
appliances without losing pressure to any appliance. A properly sized and installed gas line will deliver a supply pressure between 7.0"
W.C. (17.4 mbars, 1.74 kPa) and 10.0" W.C. (24.9 mbars, 2.49 kPa) natural gas or between 11.0" W.C. (27.4 mbars, 2.74 kPa) and
13.0" W.C. (32.4 mbars, 3.25 kPa) propane to all appliances connected to the supply line, operating simultaneously at full demand. The
pressure at the gas valve must not exceed 1/2 PSI.
Each appliance is equipped to operate on one certain fuel type. The type of fuel with which the appliance is intended to operate is
stamped on the data plate, which is attached to the inside of the door.

INSTRUCTIONS

The area around the appliance must be keep free and clear of combustibles such as solvents, cleaning liquid, broom, rags, etc.
All threaded joints of the appliance piping must be sealed with a compound that is resistant to the action of natural gas or liquefied
petroleum gases and the joint connection checked for gas leaks using a soapy water solution before lighting the pilots.
Proper clearances must be provided at the front of the appliance for servicing and proper operation.
For proper combustion and ventilation, provisions shall be incorporated in the design of the kitchen to ensure adequate supply of
fresh air and adequate clearance for air openings into the combustion chamber.
For proper operation of the appliance, do not obstruct the flow of combustion and ventilation air.
A manual gas shut-off valve shall be installed when the appliance is connected to the gas supply.
The rating plate is located on the outside of the right side of the panel.
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
Pasta Cooker

INSTALLATION

The installation instructions contained here are for the use of qualified
installation and service personnel only. Installation or service by other
than certified / licensed personnel will void the warranty and will result
in damage to the pasta cooker and/or injury to the operator.
4