ディスペンサー Bobrick B-828のPDF トラブルシューティングマニュアルをオンラインで閲覧またはダウンロードできます。Bobrick B-828 3 ページ。 Automatic counter-mounted soap dispenser
Bobrick B-828 にも: 取り付け方法 (4 ページ), クリーニングとメンテナンス (2 ページ)
for Bobrick B-828 SureFlo
Step 1: To determine cause: Unplug unit and reconnect unit look for Green LED light and sound of motor. Activate soap dispenser continually five times.
If motor running and LED does not light up consistently when hand is in the activation zone.
Likely Cause
Fiber Optic Nut may be thread
too tight onto connector port in
the Bottom Housing.
No change.
If motor running and LED lights up.
Likely Cause
Clogged Nozzle Tip.
Soap may be too viscous.
If unit requires multiple (more
than 5) activations to dispense
foam. Duckbill inside Foam
Mixer Housing may be stuck
open.
No change.
If motor not running and LED lights up.
Likely Cause
Issue with Power Source this
is determined by Flasing RED
LED.
Gear jamming.
Flashing red LED. Indicates
sensor obstruction.
No change.
If motor not running No LED light.
Likely Cause
No power to the unit
No change.
Likely Cause
Loose Stem connection to
Bottle Cap.
Leaking from bottom of Bottom
Housing.
Likely Cause
Foam Soap too Airy.
Foam Soap too Liquidy/
Watery.
Troubleshooting Guide
Automatic, Top Fill Bulk Foam Soap Dispenser
®
Action
Check Fiber Optic Nut to see if nut has
been overtightened
All steps above completed.
Action
Remove Nozzle Tip.
Ensure that soap meets specified
viscosity range.
Viscosity less than 100cps (CPS = center-
poise) Adjust viscosity and Flush system.
Flush whole system.
All steps above completed.
Action
Check batteries. Check A/C adapter
connection.
Check for dried soap. Purge system.
Ensure all obstructions have been
removed from sensor path.
All steps above completed.
Action
Replace with new batteries. Check A/C
adapter connection.
All steps above completed.
Action
Unscrew Stem Locking Nut.
Locate leak if from bottom of Bottom
Housing.
Action
Adjust portion control knob. Also check
Nozzle Tip Mesh Screen.
Adjust portion control knob. Also check
Nozzle Tip Mesh Screen.
Instruction
Tighten Fiber Optic Connector Nut hand tight and then rotate nut
counterclockwise by 1/4 turn (90°).
Contact Bobrick Customer Service.
Instruction
Clean with warm water and replace. Flush whole system. If Nozzle
continutes to be clogged replace.
Flush whole system. Replace with soap that is within recommended
viscosity range.
If still requires multiple activations, order new Foam Mixer Housing.
Contact Bobrick Customer Service
Instruction
Replace with new batteries. Reconnect A/C adapter connection. If
problem persists, send unit back to manufacturer.
Open Cover and pour warm water and then purge.
Refer to mounting template.
Contact Bobrick Customer Service
Instruction
If problem persists, send unit back to manufacturer.
Contact Bobrick Customer Service
Instruction
Push the Bottle Assembly up onto the Stem until it stops. While pushing
upwards on the Bottle, thread the Stem Locking Nut down onto the
Bottle Cap threads. Reference Instruction Sheet 828-391.
Unit needs to be returned. Replace with Bottom Housing Replacment Kit.
Instruction
Turn knob clockwise for less air in foam. Clean Mesh Screen and /or
replace.
Turn knob counter clockwise. If Mesh Screen is torn replace.
Replacement
Part/Kit Needed
n/a
n/a
Replacement
Part/Kit Needed
828-310
n/a
828-322
n/a
Replacement
Part/Kit Needed
n/a
n/a
824-307
n/a
Replacement
Part/Kit Needed
n/a
n/a
Replacement
Part/Kit Needed
n/a
828-550
Replacement
Part/Kit Needed
828-310
828-310