Screw
Name
Terminal #
1
PowerA
2
PowerB
3
GroundA
4
GroundB
5
GroundC
6
CANH
7
CANL
8
Pressure sensor
input
9
5[V] output
10
12[V] protected
output
For PowerA and PowerB each should be connected through the supplied fuse holders and 15A fuses. The best place to tap power is generally
after the ignition switch or any other source of power that is always "live" when the engine is running. If the Lambda sensor is in an active
exhaust stream and unpowered, carbon from an active exhaust can easily build up on an unpowered sensor and ruin it.
You can ground all the grounds to the same point.
For all Oxygen sensor installations the sensor must be installed before the catalytic converter.
For normally aspirated engines the sensor should be installed about 2ft from the engine exhaust port. For Turbocharged engines the sensor
should be installed about 3ft from the engine exhaust port after the turbocharger. For Supercharged engines the sensor should be installed 3ft
from the engine exhaust port
MegaSpartan User Manual, Release Date: Aug 22 2018
8
7
6
5
4
Connects to
12v
12v
Ground
Ground
Ground
MegaSquirt CAN Bus
High
MegaSquirt CAN Bus
Low
Pressure Sensor
Output
Not currently used. This terminal is protected by; fuse, diode (reverse
polarity protection), and Transient Voltage Suppressor.
Lambda Sensor Installation
The Lambda Sensor should be installed between the 10 o'clock and the 2 o'clock position,
less than 60 degrees from vertical, this will allow gravity to remove water condensation
from the sensor.
3
2
1
Note
Use 15A fuse
Use 15A fuse
Can connect all grounds to same point
Can connect all grounds to same point
Can connect all grounds to same point
Provides 5[V] power to pressure sensor