- ページ 3

室内装飾品 American Standard Metering 1340.725のPDF インストレーション・インストラクションをオンラインで閲覧またはダウンロードできます。American Standard Metering 1340.725 3 ページ。 Spread lavatory faucets
American Standard Metering 1340.725 にも: パーツリスト (1 ページ), インストレーション・インストラクション (4 ページ)

American Standard Metering 1340.725 インストレーション・インストラクション
5
INSTALL HANDLES
Remove INDEX BUTTON (1; 2) and loosen SET
SCREW (3) with a 2.5mm hex wrench.
Install HANDLES (4) onto VALVE STEM (5).
Tighten SET SCREWS (3) with 2.5mm Hex Wrench.
Replace INDEX BUTTONS. Red (1) in Left HANDLE (4)
Blue (2) in Right HANDLE (4).
6
TEST INSTALLED FITTING
Turn on water supplies and check connections for leaks.
Remove AERATOR (1) with KEY (2) supplied.
Operate HOT and COLD HANDLES by pressing down on HANDLES.
Both Hot and Cold handles are set for approximately 8 second operating cycles.
Replace AERATOR (1).
7
TO ADJUST CYCLE TIME
Remove HANDLE (1) by removing INDEX BUTTON (2)
and SET SCREW (3) with a 2.5mm hex wrench.
Pull off HANDLE (1).
To increase cycle time, turn the gray PLASTIC ADJUSTING
KNOB (4) clockwise.
To decrease cycle time, turn the gray PLASTIC
ADJUSTING KNOB (4) counter-clockwise.
Replace SET SCREW (3), INDEX BUTTON (2) and
HANDLE (1). Test faucet for proper operation and
cycle time.
2
3
2.5mm HEX WRENCH
TO DECREASE
CYCLE TIME
ROTATE
COUNTER-
CLOCKWISE
4
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR
WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH
WITH A COARSE SURFACE.
1
TO INCREASE
CYCLE TIME
ROTATE
CLOCKWISE
1
4
3
PRESS HANDLE
DOWN TO OPERATE
8
SERVICE
Remove HANDLE (1). Refer to Step 3 for handle removal.
Remove ACTUATOR ASSEMBLY (1).
Remove WASHER (3). Pull out VALVE ASSEMBLY (4) and
FILTER SCREEN (5).
Inspect that VALVE ASSEMBLY (4), FILTER SCREEN (5) and
VALVE SEAT (6) are clean and free from debris. VALVE
ASSEMBLY (3) and FILTER SCREEN (5) can be cleaned with
soap and water.
Replace FILTER SCREEN (5), VALVE ASSEMBLY (4) and WASHER (3).
Place WASHER (3) on top of VALVE ASSEMBLY (4). Thread VALVE
ACTUATOR (2) onto faucet. Torque VALVE ACTUATOR (2)
to 12-15 ft. lbs (15-20 Nm).
Replace HANDLE (1).
REMOVE
Attention; Sealing washer (3) should be
replaced everytime VALVE ACTUATOR (2)
is removed.
3
4
2.5mm
HEX WRENCH
5
1
REPLACE
2
3
4
5
6
M 9 6 8 4 9 2 R ev. 1. 5
2
1
2