バスタブ American Standard Durabond 2908.020のPDF インストレーション・インストラクションをオンラインで閲覧またはダウンロードできます。American Standard Durabond 2908.020 2 ページ。 Reminiscence bathtub

INSTALLATION INSTRUCTIONS

THANK YOU... for selecting an American Standard . . . the benchmark of fine quality for over 100
years. To ensure that your installation proceeds smoothly--please read these instructions carefully
before you begin. All you need to finish the installation are your selected fittings. (Certain installations
may require professional help.) Also be sure your installation conforms to local codes.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any
shipping damage. If such damage is found, report it to
your vendor immediately.
Protect all finished surfaces of the bath during
construction and installation using a drop cloth. If
packaging foam is removed for inspection purposes,
save for foot installation procedure.
Fittings (bath filler, drain, feet, and water supplies) are
not provided with the bath and must be ordered
separately.
Fig. 1
953mm
(37-1/2)
C/L
OUTLINE OF
SKID RESISTANT
SURFACE
1832mm
(72-1/8)
870mm
(34-1/4)
692mm
REF.
(27-1/4)
REMINISCENCE
FINISHED
FOOT
FLOOR
FOR AFTER-SALES SERVICE CALL 1 (800) 223-0068 WEEKDAYS.
752515-100 Rev. D
C/L OF 1/2 NPT
SUPPLIES
57mm
108mm
(2-1/4)
(4-1/4)
343mm
(13-1/2)
89mm
(3-1/2)
TYP.
H
114mm
(4-1/2)
C
*
724mm
(28-1/2)
C/L OF
114mm
DRAIN
1/2 N.P.T. INLETS
(4-1/2)
FINISHED WALL
584mm
(23)
38mm
REMINISCENCE
(1-1.2)
BALL &
CLAW FOOT
1-3/8 O.D.
TAILPIECE
List of Required Components (not included):
• 1591.170 Drain*
• 9112.017 Bath Filler*
• 9114.012 Water Supplies*
• 9111.039 Ball & Claw Feet
• 9110.039 Reminiscence Feet
* Available at your American Standard Distributor
List of Required Tools and Supplies:
Tools
FINISHED WALL
• Drill
368mm
• Drill bits for wood
(14-1/2)
324mm
(12-3/4)
• Level
203mm
• Tape Measure
(8)
• Pipe Wrench
• Crescent Wrench
• Slip Joint Pliers
699mm
(27-1/2)
• Screw Driver
• Standard
• Personal Safety
• Caulking Gun
508mm (20)
WALL FLANGES
W/SCREWS
INSTALLED SIZE
PROVIDE CROSS
BRACING IN WALL
FOR ANCHORS
WEIGHT
C/L OF
WEIGHT w/WATER
OVERFLOW
GAL TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
140mm
(PROJECTED AREA)
(5-1/2)
PTS.
CUBE (FT
127mm
(5)
INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS
464mm
(18-1/4)
WITH HOMEOWNER AS THEY PROVIDE IMPORTANT
REF.
CLEANING INFORMATION.
HIGH GLOSS ACRYLIC
FITTINGS NOT INCLUDED
Supplies
• Putty
• Caulking (silicone)
or tile
• 1/4" - 20 x 3"
• flat washers
• 1/4" lockwasher (4)
• 1/4" nut (4)
• Masonry Anchor
Woodworking Tools
• 5/16" Lag Bolts
Equipment
GENERAL SPECIFICATIONS FOR 2908 BATHING POOL
22 LBS./Sq. Ft. (107 Kgs/Sq. m. )
3
)
© American Standard Inc. 2002
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
toggle bolts
(as required)
(concrete installations)
(wood floor installations)
72-1/8 x 37-1/2 x 27-1/4 In.
(1832mm x 953 mm x 692mm)
130 Lbs. (59 Kg.)
413 Lbs. (186 Kg.)
34 Gal. (129 L)
18 x 42 In. (457mm x 1067mm)
67 x 31 In. (1702 x 787mm)
14 In. (356 mm)
23.8
48.3