- ページ 6

トイレ American Standard Baby Devoro 2282のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。American Standard Baby Devoro 2282 13 ページ。 Baby devoro flushometer bowl
American Standard Baby Devoro 2282 にも: 取付説明書 (14 ページ)

American Standard Baby Devoro 2282 取付説明書
Fig. 1
Roughing-in Dimensions
72mm
(2-7/8)
116mm
(4-5/8)
MANUAL
OVERRIDE
BUTTON
*CRITICAL
LEVEL
-C-L-
X
-C-L-
MODEL
X
Y
6065.121
293mm
409mm
6065.161
(11-1/2)
(16-1/8)
6065.122
683mm
799mm
6065.162
(27)
(31-1/2)
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Water Closet
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
DETECTION ZONE
(15-3/4 TO 31-1/2)
SUPPLY
DN 25mm
(1" I.P.S.)
115mm-134mm
(4-1/2 TO 5-1/4)
Y
FOR 1-1/2" TOP
SPUD FIXTURES
-C-L-
165mm
*Note: The Critical Line (-C-L-) on Vacuum
(6-1/2)
Breaker must typically be 6
565mm
fixture. Consult Codes for details.
(22-1/4)
400mm-800mm
FINISHED WALL
57mm
(2-1/4 MIN.)
15˚
"
(152mm) above
Fig. 2
1
5
7
• Flush all water lines prior to operation (See Step 4). Dirt
and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use
pipe sealant or plumbing grease on any valve component
or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
2

GENERAL DESCRIPTION:

SELECTRONIC™
PROXIMITY TOILET
FLUSH VALVE
Exposed Flushometer
for 1-1/2" Top Spud Fixtures
Exclusive, self cleaning piston-type flush
valve with proximity operation and
manual override.
Operates on DC
(b at ter y) pow er . R eco mm en ded
operating pressure 35 to 80 psi. Can
install left or right-handed. Detection
Zone can also be adjusted manually, or
with optional remote control.
Right or Left Hand Installation
(Section 5)
See
for converting Flush
Valve to Left Hand Installation.
2
3
4
10'
6
9
10
M968699 Rev. 1.6
8