- ページ 14
サーモスタット American Standard ACONT203AS42MAのPDF インストールとユーザーマニュアルをオンラインで閲覧またはダウンロードできます。American Standard ACONT203AS42MA 20 ページ。
Installation and User Guide
4.6
Installer Menu
To prevent changes that may affect system performance, this thermostat has an INSTALLER MENU and a USER MENU. The
INSTALLER MENU provides access to every option, while the USER MENU provides access to items that will not affect system
performance. To access the INSTALLER MENU press the Menu button for 8 seconds. The display will show item 05 in the table below.
Use Next and back to navigate through menu items. Press
INSTALLER MENU
(HOLD MENU 8 SEC-
ONDS)
Outdoor Equipment: selects air conditioner (AC) or heat
05
pump (HP) equipment as well as the number of stage
Indoor Equipment: selects whether the equipment is a
10
gas furnace, electric furnace or fan only
dE
Dedicated Emergency: W/E only operates in Emergency
15
Aux mode. W2 becomes 1st stage Aux. Heat
R
20
O,B or 3 Wire Zone Valve Selection
Circulation fan: sets the minimum % of time for the fan
Fn
25
to run (takes into account the fan run time with heat/cool
equipment)
CR
30
Heat Cycle Rate: how often the heat will turn on
CR
32
Aux Cycle Rate: how often the auxiliary heat will turn on
CR
35
Cool Cycle Rate: how often the cooling will turn on
CL
Compressor Lockout:
50
protects the compressor from short cycling
65
Max Heat Limit: maximum set point for heat mode
66
Minimum Cool Limit: minimum set point for cool mode
Schedule Type: set as either 7-Day, 5-1-1 Day or Non-
74
Programmable
75
Defines periods per day
Early Start: starts heating or cooling early so your
E
76
programmed temperature is reached by the programmed
time
79
Fahrenheit or Celsius
Temperature Display Adjustment: adjust the displayed
81
"Room Temperature"
dL
Continuous Display Light: keep the backlight always on –
83
"C" wire required
86
Change Air Filter: set up a monthly reminder
Auto Changeover: thermostat automatically switches
88
between heat and cool
Keypad Lock: prevent unwanted changes to the
99
thermostat
14
or
or to change a menu setting.
DESCRIPTION
DEFAULT SETTING
(FLASHING ICONS)
AC2
EL2
OFF
O
OFF
MEd
MEd
MEd
ON
99
45
5
4
OFF
°F
0
OFF
OFF
OFF
OFF
Pub. No.
11-HD19D1-1D-EN
SETTINGS
(PRESS
OR
)
AC0
AC1
AC2
HP1
HP2
FAN
GA1
GA2 (conventional only)
EL1
EL2 (conventional only)
On
OFF
O
B
3
OFF, 10 TO 100
SLO – slow
MEd – medium
FAS – fast
SLO – slow
MEd – medium
FAS – fast
SLO – slow
MEd – medium
FAS – fast
On – 5 minute delay
OFF – no delay
47 to 99
45 to 97
7 – 7 Day
5 – 5-1-1 Day
0 – Non Programmable
2 – P1, P2
4 – P1, P2, P3, P4
On – start early
OFF – start at program
period time
°F – Fahrenheit
°C – Celsius
-5 to +5
On – always on
OFF – momentarily
1 to 12 – reminder time
(months)
OFF – no filter reminder
On – enable auto
OFF – disable auto
On – disable buttons
OFF – all buttons are active
09/2020
Part No. 37-7777006