- ページ 8

キッチン&ランプ; バス備品 American Standard Paradigm Selectronic 7025.3 SeriesのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。American Standard Paradigm Selectronic 7025.3 Series 9 ページ。 Integrated faucet with optional above-deck mixing & smartherm

American Standard Paradigm Selectronic 7025.3 Series 取付説明書
ADJUST OR REPLACE MAXIMUM
D
OUTLET TEMPERATURE; Fig. 10
1. With the COVER off, the installer can reduce the maximum mixed
water temperature by turning the THERMO VALVE (4) clockwise
with a screwdriver.
2. Remove SCREW (6) and unthread THERMO VALVE (4).
Replace with new THERMO VALVE (4).
WARNING
• Do not turn the THERMO VALVE (4) More than 1 turn.
• The maximum mixed water temperature can not be
increased due to ASSE 1070 requirements.

GENERAL CLEANING

E
1. Only use a damp, soft cloth to clean the spout and the sensor.
2. For tougher dirt, use a soft cloth with diluted dish washing
detergent. Wipe the area using a wet cloth and dry using a
soft cloth.
CAUTION
Do not scratch the sensor when cleaning. Avoid using
any abrasives or harsh detergents or chemicals.
Fig. 12
6
4
Fig. 10
8
3
5
M965985 (11/18)