ELECTRICAL INSTALLATION

Product
DC Long Life Power Pack
T064.342 / T064.345
DC Standard Battery
T064.353 / T064.355
AC Plug-in
T064.362 / T064.365)
AC Hardwire
T064.392 / T064.395)
AC Multi Hook-up
T064.372 / T064.375)
A
LONG LIFE POWER PACK
& STANDARD BATTERY; Fig. 1
1. Remove ENCLOSURE COVER (1) from
ENCLOSURE (2). Fig. 1.
2. Feed the EXTENSION CABLE (3) from the Faucet
through SIDE GROMMET (4). Fig. 1a.
3. Connect SOLENOID CABLE (5) to EXTENSION
CABLE (3) from the Faucet. Fig. 1a.
4. Insert BATTERY (6) into BATTERY HOLDER (7),
make sure the shape of the BATTERY (6) follows the
shape of the BATTERY HOLDER (7) and terminal
end is inserted first. Fig. 1b.
!
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is
self adjusting. Keep detection zone clear for 15
seconds after power is connected.
5. Connect the BATTERY CONNECTOR (7a) from the
Standard or Long Life Power Pack to EXTENSION
CABLE (8) as shown. Fig. 1c. Place Standard
Battery or Long Life Power Pack into Housing.
Fig. 1d.
6. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.
CAUTION: Use only American Standard supplied
cable sets. Using non-AS supplied cables, or
cutting, splicing or modifying any components will
void the warranty.
Fig. 1
Page
6
6
Fig. 1a
7
7
3
8
Fig. 1c
Fig. 1d
6
Fig. 1b
4
5
7a
8
5
1
2
7
INSTALL BATTERY
6
- P 2
C R
STANDARD
BATTERY
LONG LIFE
POWER PACK
7a
STANDARD
BATTERY
LONG LIFE
POWER PACK
M 9 6 5 6 13