- ページ 13

浄水器 AmeriFlow Water Systems Inc. ET6500GROのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。AmeriFlow Water Systems Inc. ET6500GRO 15 ページ。 Reverse osmosis systems

AmeriFlow Water Systems Inc. ET6500GRO オーナーズマニュアル
Water does not
Bad membrane.
taste or smell
right.
Filters have expired.
Little water use.
System needs sani-
tizing.
Little water from
Over pressurized
faucet.
tank.
Incoming water pres-
sure is below 40 PSI.
New system or filters
just changed.
Bad check valve.
Tank valve not open.
Bad storage tank.
Filters clogged.
Kinked tube.
System is con-
Shut off valve not
tinually running.
working.
Low city supply water
pressure.
Bad check valve.
Ice being made in
refrigerator.
System is new.
Ice maker not
Ball valve to ice line
working.
is off.
Ice maker in refrig-
erator is off.
Ice maker line frozen.
Tube to refrigerator is
kinked.
No water out
1-quart reservoir
of refrigerator
not full.
door.
Makes water
Normal R/O process.
slowly.
Low city water pres-
sure.
Kinked tubing.
Filters plugged.
Bad membrane.
Replace membrane when below 75% rejection and
sanitize.
Replace filters. Should be replaced every 6 to 12
months.
Drain or use entire tank. Should be done every 2 weeks
if low water use.
Sanitize (see Step 11: Recommended Sanitizing In-
structions) and replace filters.
When empty, tank pressure should be between 5-12
PSI.
Increase pressure to 40 PSI with a pump.
System takes 4 to 12 hours to completely fill.
Replace check valve.
Open valve.
Replace storage tank. If not bad check that tank air
pressure is between 5-12 PSI when empty.
Replace filters.
Un-kink tube. If damaged, replace tube.
Replace shut off valve.
Increase water pressure to 40 PSI with a pump.
Replace check valves.
Nothing you can do, ice is made on demand.
Allow 2 weeks for air to bleed.
Turn on ball valve.
Turn to on position.
Thaw with hair dryer. Make sure you have a full tank of
water before turning ice maker on.
Find kink and repair.
Hold down dispenser handle for approximately 3 min-
utes until water comes out. Make sure R/O tank is full.
Your R/O system makes water a drop at a time. 3-gallon
storage tank should be full in 4-12 hours.
Increase to 40 PSI. with a booster pump.
Find kink and repair.
Replace filters.
Replace membrane.
12
07\15 RO Manual