ウォーターヒーター Air Delights E-70のPDF 設置および操作方法をオンラインで閲覧またはダウンロードできます。Air Delights E-70 4 ページ。 Chronomite instant-temp water heaters
CHRONOMITE INSTANT-TEMP WATER HEATERS
INSTALLATION AND OPERATION INSTRUCTIONS (STANDARD MODELS)
Model
E-30
E-30
E-30
E-30
E-46
E-46
E-46
E-60
E-60
E-60
Instant-Temp Specifications:
•
Dimensions:
•
Weight:
•
Materials:
•
Color:
•
Inlet/Outlet:
•
Pressure
Requirements:
•
Maximum Operating
Temperature:
•
Flow Switch
Activation:
•
Listings:
THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGES DUE
TO THE FAILURE TO FOLLOW THESE INSTALLATION AND OPERATION INSTRUCTIONS
CAUTION:
1.
Remove heater cover. Attach conduit to the conduit through electrical access hole. Then feed wires. Do not attach
wiring yet.
2.
Mount unit horizontally against the wall so label reads correctly (See Fig. 1). Mount with four screws through the
mounting holes located on the base plate housing using molly anchors or fasteners. CAUTION: Heating elements may
burn out if unit is not mounted horizontally.
3.
Connect plumbing. Use ¼ inch tapered national pipe thread at cold-water inlet and hot water outlet (See Fig. 1). Use
compression fittings for ease of installation and possible servicing. Do not apply heat to these fittings.
4.
Run water through the unit to expel all air bubbles. Check for leaks at all fitting joints.
5.
Connect wiring. Attach ground wire to center terminal and hot wires to outer terminals (See Fig. 3).
6.
Install cover. Install the (2) cover mounting screws. Turn on circuit breaker. The unit is now ready for use.
7.
The LED indicator located on the front cover will indicate that the power is "on". Local plumbing and electrical codes
must be followed in this installation of water heater and the accessories.
8.
Failure to comply with code requirements voids warranty.
9.
Optional (if potentiometer is to be used , install at time of installation; see page 3 for further instructions):
Mount potentiometer to wall using bracket supplied as shown in diagram
a. Connect the quick connect of the potentiometer to the connection found on the lower right side of the heater.
(Before installation, compare electrical needed for the model of heater selected)
Wattage
Voltage/AC
3000
110-120
3000
208
3000
220-240
3000
277
4600
208
4600
220-240
4600
277
6000
208
6000
220-240
6000
277
10
x 7
x 2 ¾
3/4
5/16
8 lbs
Rugged Steel housing, plastic element
Assembly with nichrome parts
White
Female ¼ NPT Standard Pipe Thread
45 PSI (20-40 PSI LP Models)
150 PSI maximum. No pressure relief
valve needed, unless required by local code.
140 °F
Heating Coil switch activates at 1.0 GPM
And deactivates at .65 GPM
UL, IAMPO
BEFORE BEGINNING THE INSTALLATION:
A)
Turn off circuit breaker to avoid dangerous electrical shocks.
B)
Turn off water supply.
TABLE 1
Breaker
Model
Wattage
30
E-70
7000
15
E-70
7000
15
E-70
7000
15
E-80
8000
30
E-80
8000
20
E-80
8000
20
E-90
9000
30
E-90
9000
30
30
Voltage/AC
Breaker
208
40
220-240
40
277
30
208
40
220-240
40
277
30
220-240
40
277
40
1