6. PUMP INSTALLATION

Not applicable for models Fekabox 200 – Fekafos 280 – Fekafos 550 which have the pump already fitted
inside.
Ensure that the difference in level between the pump and the sewage network is compatible
with the pump performance.
Fekabox 200 l: For references of the details see diagram on page 41
The Fekabox range is equipped with a 2" and 1"1/4 polypropylene lowering device with anti-rotation bracket,
and therefore intended for only one automatic single-phase pump with float ≤ 20Kg.
A. Remove the tank cover.
B. Extract the slide (3) from the coupling foot (5)
C. For FEKA 600: screw the special 2"F-1"1/4 M coupling (2.1), onto the lifting slide (3), and of the pump
(see fig. 7)
D. For FEKA VS-VX
the slide (3) onto the pump body (see fig. 7)
Remove the screw (1) from the pump body
Assemble the anti-rotation bracket (2) on the slide and then re-tighten the screw (1)
check that the length of the pump float is 250 mm (see page 41, fig 8A).
E. Reposition the slide/pump assembly on the foot (5) already fixed inside the tank.
1
5
Fig. 7
Feka VS-VX
2
3
ENGLISH
45
3
2.1
5
Feka 600