Kindling order of the boiler
Before kindling the boiler, check whether all requirements indicated in the section 1 are
executed.
Open the damper of the upper flue (C) by pushing the handle (12) towards yourself (see fig. 2).
Open the door (9) of the upper combustion chamber (2) and put dry kindling wood on the heat-
resistant shell (3) to form 2-3 cm gap between the opening of the shell and kindling wood. Put some
of the easy flammable materials and bigger kindling wood and firewood atop. Fire the kindling
wood, wait till the firewood combusts, close the door and turn the handle (12) of the flue damper
from yourself to the end. Load the wood without any bigger spaces until the top of combustion
chamber. Bigger pieces of firewood should be loaded in the middle and smaller prices – at
the sides, because the walls of the combustion chamber due to their lower temperature
slows down the combustion of the bigger pieces of wood. Do not cover with the wood the hole
of the smoke extraction valve C . With the boiler control panel switch the tension of the electronic
controller with the button „0"-„I" ( see the technical description of the electronic controller). There
will be switched on the lights and temperature indicator. Using the buttons of the temperature
regulation set required temperature of the water flowing of the boiler – it is recommended to set on
0
the 70
C. Close the upper door of the combustion chamber, open the lower door, burn the wood
pieces ., Leave the lower door open until the water temperature in the boiler reaches 40
the lower door, close the valve of the upper smoke traction by pushing the handle of valve (12) to
the end. Switch-on the ventilator with the control panel.
automatic range and will maintain the set temperature of the water from the boiler.
WARNING! The door of the boiler combustion chambers should be tightly closed, there
should be no flammable products accessing the exterior. Door tightness is regulated by screwing or
unscrewing hinge and lock screws of the door.
Regulation of the boiler temperature – see the technical description of the electronic
regulator.
Emergency thermostat of the water temperature (safety switch ! 95
If the water temperature due to the unforeseen reasons exceeds the maximal allowable limit ,
safety thermostat (emergency switch), switches off the ventilator of the air supply. Combustion
intensity will decrease and the temperature of water will drop.
When the emergency thermostat comes into action (switches off) – the light of the ventilator switch
and electronic controller is off , it is necessary to detect the reasons and to remove them.
Emergency thermostat is turned on by taking off the cover of thermostat ! 108
red button. .
The attempts of purchaser to repair the thermostat and to recover its functions on his own without
removal of reasons which caused the over-heating of boiler can result not only serious damages of
boiler, but also the danger for the health and life. If the reasons of the switch of the emergency
thermostat can not be detected and removed, it is necessary to call the servicing company !
Addition of the firewood
While putting firewood into the combustion chamber (during boiler operation or after load
burning off), keep strictly to the set order:
1) Open the damper of the upper flue by pulling the handle (12) (see fig. No. 2).
2) Switch off the ventilator.
3) Wait at least 20 s, open the upper door.
4) Put the firewood in and close the door tightly.
5) Switch on the ventilator.
6) Close the damper.
If operated following this order, smoke and carbon won't enter the room.
Combustion control
The combustion control of boiler is described in the chapter "COMBUSTION CIONTROL"
of the technical description of regulator KR-4.
The flame in the boiler can be checked by opening the lower door of the combustion
chamber when the ventilator is on.
Temperature regulation of the heating system – See the description of the scheme
of boiler room ( beginning of the chapter 4).
Cleaning of the boiler
Aches are removed from the boiler each 4-7 days. Open the door of the upper combustion
chamber and shovel aches down to the lower chamber. Open the door of the lower chamber, take out
the ceramic inserts and shovel ashes to the metal box.
WARNING! In any case keep strictly to the determined order: open the damper of the
upper flue, then after 20 s open the boiler door.
Afterwards the boiler will work on the
o
C ).
o
C and pressing the
0
C. Close