4.5. MOUNTING BASE AND CLAMp A INSTALLATION
Front view
use ∅8 mm bolts and ∅14 mm anchors to fix the mounting base on the column.
The mounting base should be placed at a distance of not less than 150 mm from the ground.
Fix clamp A on the gate leaf (use ∅8 mm bolts or welding). clamp A should be placed at a distance of 450 mm from the hinge,
horizontally, and 19 mm from the mounting base installed on the column, vertically (see the picture above).
4.6. OpERATOR INSTALLATION
Install the operator on the mounting base: match four holes and fix using 2 supplied bolts M8×110 mm.
To install the operator on the right leaf, change the position of the operator and use other two pairs of holes (see the picture
above).