- ページ 15

水ポンプ Astralpool DMX Variable Pump SのPDF インストレーション、オペレーション、メンテナンスマニュアルをオンラインで閲覧またはダウンロードできます。Astralpool DMX Variable Pump S 19 ページ。

Astralpool DMX Variable Pump S インストレーション、オペレーション、メンテナンスマニュアル
2.2

WIRING AND PIPING

2.2.1
Hydraulic
Connect the pipe and the thread nozzle to the impulsion of the pump (③)
(1-1/2" RH).
WARNING: Risk of unit damage. Do not assembly directly the nozzle and rigid pipes
to the pump to avoid breakages. Make use of flexible pipes and holders for LED
lighting and nozzles.
WARNING: Risk of unit damage. Clean all piping prior to connecting and starting the
unit up.
2.2.2
Electric
Connect the equipment to 24V DC power supply protected by 30mA differential
circuit breaker, a magnetothermal circuit breaker and earth connection. In addition,
use a galvanic separation between the primary and secondary side.
Connect the DMX wire to the control panel. Use a waterproof DMX wire.
Up to 32 pumps can be connected to the same DMX bus (see diagram).
DMX connector between pumps is not included.
WARNING: Risk of unit damage. Check that all IP68 connectors are properly sealed
and they prevent water getting through. Electrical components may become
damaged by flooding, causing the unit warranty loss.
3

OPERATION AND MAINTENANCE

WARNING: Protect the water outlet from wind and do not operate in strong wind. If
the unit is installed in a windy area, water outlet could be often displaced.
INSTALLATION, OPERATION AND MAINTENANCE MANUAL; DMX VARIABLE PUMP S
[en]
Fountain Units
15