バーコードリーダー Cognex DataMan 8000 SeriesのPDF クイック・リファレンス・マニュアルをオンラインで閲覧またはダウンロードできます。Cognex DataMan 8000 Series 17 ページ。 Cognex dataman 8000 series barcode reader

Use the Setup Tool Menu Bar
Each reader can store its current set of run-time parameters to a coniguration
(.cfg) ile, which contains information such as the enabled symbologies and
how any output data should be formatted.
The same coniguration ile can be loaded onto multiple readers, as the ile
does not contain identiication information such as the IP address or device
name of the reader used to create it.
A reader can also generate a Cognex device coniguration (.cdc) ile, which
stores the set of run-time parameters plus any identiication data, such as
the name of the device, its IP address, subnet mask, and so on. Cognex
recommends generating a device coniguration ile for each reader to allow you
to restore a reader to its operating state with minimal effort.
Use the File menu of the Setup Tool to manage .cfg and .cdc iles:
File Menu
Open Coniguration
Open a saved .cfg coniguration ile.
Save Coniguration
Create a .cfg coniguration ile of current run-
time parameters.
Restore Device
Load a saved device coniguration .cdc ile,
with run-time parameters plus device-speciic
information for a particular DataMan 8000.
Backup Device
Create a device coniguration .cdc ile for a
speciic reader.
22 DataMan 8000 Quick Reference Guide
Use the Edit menu for standard Cut, Copy and Paste operations.
Use the View menu to view reader information (serial number, irmware
version, and so on) and to enable and disable various elements of the
Setup Tool, and the Tasks menu to switch between various Setup Tool
options.
Use the System menu to manage the current settings on the reader
and to upgrade the features it currently supports:
System Menu
Save Settings
Save the current parameters to non-volatile
memory, which allows the reader to restore
these settings each time you reboot it.
Reset Coniguration
Reset all coniguration parameters in RAM
(volatile memory) to the default settings
except for communication settings.
Update Firmware
Update the reader software.
Upload Feature Key
Unlock additional features available in the
reader software if you have the right key.
Use the Help menu to display Setup Tool version information.
DataMan 8000 Quick Reference Guide 23