Low Level Programming
It is possible to configure various systems operating parameters from the keypad. This is normally done at
Astrel factory or by the spa manufacturer, but may be done at anytime. The configuration will be kept into
an EEPROM memory. To program these system parameters, the Light key must be held for 20 seconds.
After this time, the first parameter will be displayed (see below). For each parameter, use the Up/Down key
to modify its value. Light key is used to accept the new value and switch to the next parameter. The display
returns to the normal display when there is no more parameter to change. There are three (3) low-level
programmable parameters:
•
First parameter - HC/LC
With the Up/Down key is possible to select the HC (High current) or LC (Low current) options and the
speeds of the pump1
•
Second parameter – BL/O3
With the Up/Down key is possibile to select on of the two options.
If the user select BL it is possible to connect a blower or a pump single speed.
If the user select O3 it is possible to connect only an ozonator. In this case the keys on the overlay will have
the following composition: Pump1, Light, Up, Down.
•
Third parameter
With the Up/Down key is possibile to select on of the two options.
TuC
The temperature on the display is showed in ° Cels ius
TuF
The temperature on the display is showed in ° Fahr enheit.
To go from one parameter to the other one press always the Light key.
To memorize the setting up and exit from the Low level programming press the Light key.
13.
Error Messages
•
High-limit error
Heater turned off when High Limit (HL) probe temperature reaches 48ºC.
The condition keep it up until the temperature at HL probe falls below 44ºC and power is reset.
On the display appear three dots blinking.
•
Pressure switch error
Turns the heater off when there is a flow problem
The error persist until flow problem is resolved
On the display appear three dots blinking.
D:\LAVORO\CONTROLLI SPAS\MANUALI INSTALLAZIONE\MICROSPA\Instruction Microspa.doc
Astrel S.p.A.
Via Isonzo, 21/E – 34070 Mossa (GO) Italy
Tel. (+39) 0481 637301 r.a.-Fax (+39) 0481 637362
e-mail: [email protected] – www.astrel.it
Cap. Soc. € 619200. i.v.
Tribunale di Gorizia n. 3505
R.E.A. n. 049936 – M/351122
Part. IVA e Cod. Fisc. 00187070313
Sheet 6/7