- ページ 15

室内暖炉 Astria Inglenook CRP2のPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Astria Inglenook CRP2 20 ページ。 Custom series multi-sided wood burning fireplaces

GLASS DOORS
Bi-fold glass doors are optional with this fireplace. Check with your
local distributor for availability.
To install glass doors, refer to installation instructions that are in-
cluded with kit. When fireplace is in operation, doors must be fully
open or fully closed position only or a fire hazard may be created
(see Figure 28).
A fireplace equipped with glass doors operates much differently
than a fireplace with an open front. A fireplace with glass doors has
a limited amount of air for combustion. Excessive heat within the
fireplace can result if too large a fire is built or if combustion air gate
is not completely open.
IMPORTANT: The following tips should be used to assure that both
fireplace and glass door retain their beauty and function properly.
Both the flue damper and glass doors must be fully opened
before starting a fire. This will provide sufficient combustion
air and maintain safe temperatures in firebox.
The glass must be allowed to warm slowly and evenly. The tem-
pered glass will withstand a gradual temperature rise to 550° F,
which is more than a normal fire will generate. Such materials
as pitch/wax laden logs, very dry mill end lumber and large
amounts of paper or cardboard boxes. Always keep the fire well
back from the doors and never allow flames to contact the glass.
" WARNING: FIREPLACES EQUIPPED WITH DOORS
SHOULD BE OPERATED ONLY WITH DOORS FULLY
OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT
PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT
OF THE FIREPLACE OPENING, CREATING RISKS OF
BOTH FIRE AND SMOKE".
Doors Fully Closed
Fireplace Front
Doors Fully Opened
Fireplace Front
Figure 28- Glass Doors
Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water.
Do not use any abrasive material to clean glass. Do not clean glass
with any cool water if glass is still hot from the fire. To remove doors,
refer to instructions included with glass door kit.
126647-01A
OPERATION AND MAINTENANCE GUIDELINES Continued
www.Astria.US.com
GRATE
The grate is designed to provide you with the maximum solid fuel
capacity. Do not overload grate or obstruct required air space beneath
it. Always keep ashes from building up under grate.
WARNING: Risk of fire! Replace grate made for
use with this fireplace only. See Replacement Parts.
CHIMNEY
Have your chimney system cleaned and inspected regularly to ensure safe
and efficient operation.
For further operating guidelines, instructions and warranty informa-
tion, please refer to your homeowner's guide or contact your dealer.

REPLACEMENT PARTS

Note: Use only original replacement parts.
This will protect your warranty coverage for parts replaced under
warranty.
Contact authorized dealers of this product. To locate a dealer in your
area contact IHP at 1-800-655-2008. You can also visit our web site
at www.Astria.US.com.
When calling your dealer, have ready:
your name
your address
model and serial numbers of your fireplace
how fireplace was malfunctioning
purchase date
Usually, we require that the part is returned to the factory.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. Please contact your IHP dealer for any questions
or concerns a. When calling your dealer please have your model and
serial numbers of your fireplace ready. You can also visit our web
site at www.Astria.US.com.
15