- ページ 9
室内暖炉 Astria MM49VFのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Astria MM49VF 20 ページ。 Grand meridian vent free universal masonry firebox
The following are dead load weight estimates for the Grand Meridian Fireplace.
Fireplace Model
Fireplace Weight
Mortar, Rebar &
Ready Mix Concrete
Firebrick Lining
43" x 28" (8.12 ft²)
Floor Area
Other Weight Considerations:
Fireplace finished facing (surround): This information needs to be obtained from the contractor.
Table II -
Construction
Floor Members
For wood structural members having a moisture content of less than 16 per cent at time of installation and used under dry
1
conditions, the deflection resulting from L + 0.5D is permitted to be substituted for the deflection resulting from L + D.
Note that IHP cannot accept responsibility for structural floor support details. All drawings are presented as mere illustrations to
indicate the presence of the underlying floor system. It is the responsibility of the general contractor/installer to consult with a local
licensed design professional for guidance in building a proper floor support system.
Figure 8
Model
A
MM39VF
38-3/4"
MM44VF
43-3/4"
MM49VF
48-3/4"
Figure 10
Typical Anchorage
Layout
Grand Meridian Weight Determinations
Table I
MM39VF
MM44VF
809 lbs.
896 lbs.
350 lbs.
357 lbs.
333 lbs.
345 lbs.
48" x 28" (9.33 ft²)
Deflection Limits
L
S or W
I/360
---
A
F
MM49VF
987 lbs.
364 lbs.
356 lbs.
53" x 28" (10.30 ft²)
D +L
1
I/240
Figure 9
4"
10"
Fireplace
outline
8
EXAMPLE ONLY
10"
SECTION VIEW
ROTATED 90CW