NOTE: To digitally adjust platform weight for over and under limits, the
Checklimit Entry Mode C.E. menu is set to SCS option. Refer to your dealer or
Instruction manual for details.
Push-button Entry of Over and Under Limits: (optional configuration)
1) Zero the scale.
2) Place an item with the desired over weight on the scale.
3) Press and release the OVER button. The OVER and ACCEPT indicators will
light, followed by displaying "over", the current weight, then "donE" to indicate
the limit has been saved.
4) Remove the over item and place an item with the desired under weight on the
scale.
5) Press and release the UNDER button. The UNDER and ACCEPT indicators
will light followed by displaying "under", the current weight, then " d onE", to
indicate the limit has been saved.
NOTE: The Push-button entry of over and under limits (PB) is an optional
configuration in the Checklimit Entry Mode Menu. Refer to your dealer or
Instruction manual for details.
Five Band Checkweighing Operation: (optional configuration)
1) Remove all items from the scale platter.
2) Press ZERO to zero the scale. The weight display should now be zero.
3) Place an item on scale platter and wait for the motion (MOT) annunciator to
turn off, indicating a stable weight.
4) If the item is heavier than the high limit, the OVER indicator will flash. If the
item is heavier than the "over" limit but lighter than the "high" limit, the OVER
indicator will turn on. If the item is lighter than the low limit, the UNDER
indicator will flash. If the item is heavier than the low limit but lighter than the
under limit, the UNDER indicator will turn on. If the weight heavier than the
under limit but lighter than the over limit, the ACCEPT indicator will light.
NOTE: The Five band checkweighing operating mode (5BA, 5BS, 5Bt, 5Bb) is
available in four different optional configurations in the Check Weighing
Operation Mode Menu. Refer to your dealer or Instruction manual for details.
Digital Entry and Recall of High and Low Limits:
1) Press and hold the OVER button until the display shows "High" and the
OVER and ACCEPT indicators flash.
2) The current weight value of saved limit will be displayed.
3) Press either the OVER or UNDER button to increase or decrease the limit
value. Holding a button longer will cause the count to accelerate. Press
UNITS or PRINT to cancel the check limit value entry. The display will read
"abort."
4) Once the desired limit is reached, press ZERO to save the limit. The display
will read "donE."