Adjusting Unit Sensitivity
You can adjust the sensitivity of your unit by turning the dial of the sensitivity potentiometer on the
range card clockwise to increase sensitivity and counterclockwise to lessen. A 5 degree turn is all that is
necessary for most applications.
The CB-5101R-1 shown above is obsolete. However, may are still in operation. The same caveat
applies to the choke and transformer on the new CB-5101R-2.
Upgrading to the CB-5501M
If you have an older loop control system with a 3CPO accessory and are upgrading to the new CB
5501M mainboard, please note the following changes:
1) The Reset button no longer functions. The presets are immediately available using the 3
position selector switch, which makes the Reset button obsolete. Its attachment to the system
will cause manual programming to become unavailable.
2) The above may result in the need for a new connection harness, as the pin-out has changed. If
you should need assistance in reconfiguring your 3CPO for use with your new card, please
contact us and we will walk you through the process.
3) Although not absolutely necessary, we recommend that you reference the 24 VDC supply to
ground (the negative terminal of the power supply).
If you have any questions about the upgrade, please call for assistance.