FEATURES(cont'd)
Test Motion: In the Main Menu, the Test Motion Screen allows the door to be
operated with the buttons. This is used when no other controls are connected and it
is necessary to calibrate the door. In some cases, it may be easier to run the door
from the Master Controller Test Motion feature even if other controls are connected.
Open and Close Speeds:
The user can set the speeds for both opening and
closing with the Open Speed and Close Speed settings.
Acceleration/Deceleration: The user can program the rates at which the door
accelerates and decelerates, this is configurable separately for each direction.
Custom Software: Custom system software features may be added upon request.
Motion Detection: Motion sensors may be provided to open or retract the door,
including safety sensors to monitor for a person or object blocking the door path.
Fire Alarm interface: External inputs can be configured to receive input from any low
voltage source for remote control, such as a fire alarm contact closure.
PiNG Proximity Sensor Option: The Ping Sensor is a small device offered by Dado
Door that allows for door control when a person gets within a predefined distance
from the Pin sensor. The sensor is setup to detect a person( ie hand, foot, etc) within
a number of inches. The Ping Setting allows for calibrating the distance for two
devices. P1 and P2. Once the setting is adjusted, any object that comes within that
distance will trigger the door to open.
Deadband The Deadband value is based on 1" = 500. This setting in the menu
determines how precise the door should attempt to hold a position. In some cases,
this setting may be increase to reduce some oscillation or 'pulsing' motion when the
door is supposed to be stopped. The default setting is 10, which means that the
door will park typically within 10/500 of an inch precision(.02"). For an exaggerated
example, if the Deadband is set to 250, the final position of the door could be within
1/2" of the actual position programmed in the controller.