- ページ 9

フロアマシン Advance acoustic AquaClean Classic 56262640のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Advance acoustic AquaClean Classic 56262640 11 ページ。

AFTER USE

1
Turn the Master Switch and the Brush Switch OFF.
2
Unplug the Power Cord and wrap it around the handle.
3
Empty the recovery tank, rinse it clean and wipe it dry.
4
Empty the solution tank. To drain, pull the clear hose down and
off of the storage peg. When the tank is empty, put the hose back
on the storage peg.
5
Remove any dirt from the filter screen in the solution tank.
6
Put the recovery tank and its cover back on the machine.
7
Push the handle to the forward, locked position so the brush
housing raises clear of the floor. This will prevent the brush from
taking a "set".
For more compact storage, remove the recovery tank, loosen the
handle wing nuts and push the handle down over the solution
tank.
8
Perform any required maintenance before storage.
9
Store in a clean, dry place.

MAINTENANCE

POWER BRUSH

Periodically check the brush and remove any built-up string, hair or
carpet fibers.

VACUUM SHOE

Periodically check the vacuum shoe and remove any built-up string, hair
or carpet fibers.

VACUUM MOTOR BRUSHES

Have the vacuum motor carbon brushes checked every 450 hours by a
qualified Nilfisk-Advance service person. Replace the carbon brushes
if they are worn to 3/8" (9.5 mm) or less.
IMPORTANT!
Motor damage resulting from failure to service carbon brushes is not
covered under warranty. See the Limited Warranty statement.

SPRAY NOZZLE

Remove the Spray Nozzle (A) once a week and soak it overnight in a
vinegar and water rinse to remove chemical deposits.

LUBRICATION

Once a month (or every 30 hours) lubricate all pivot points associated
with the valve assembly on the bottom of the machine. For best results,
use a spray silicone lubricant.
revised 2/01
FORM NO. 56041303 - AquaClean
A
CLASSIC - 9