4.4 Report generation

The unit generate from log files while running. If you encounter an issue, you need to generate a
report. This report will contain the log files and some information on the current state of the unit.
It will help the technical support team to identify the issue.
To generate this report, connect to the unit as admin with Ethernet with a ssh connection or with
the RS232 serial port and execute the following command:
type:
/doremi/sbin/report.sh <enter>
This will generate in directory /doremi/tmp a file with name drmreport_yyyy-mm-dd.tgz where
yyyy is the year, mm is the month and dd is the day. For example:
/doremi/tmp/drmreport_2007-08-16.tgz.
Send this file to the technical support team when contacting them.

4.5 Configurations

4.5.1 Boot configuration files

Configuration files can be present to specify a configuration different that the default one to be
used at boot time. Those files, when present are used during the boot sequence to set the unit
accordingly. Change those file will only take effect after the next reboot of the unit.
Such files are text file present in directory /doremi/etc/beluga
To change or create a configuration file, use the following procedure:
-
connect to the MB-4K via Ethernet using a ssh connection or via the RS232 serial port
run the beluga_conf application with the configuration file name and the value to set it to
-
as 2 parameters (in that order) :
/doremi/bin/beluga_conf configuration_file_name value
See the following sections for the allowed configuration names and value associated.
Note 1: configuration file names are case sensitive.
Note 2: those configuration files and setting method are used since software 0.1.2-8.

4.5.2 Manual configuration

The different configurations can be set manually at anytime, taking effect immediately. Those
configurations will be lost at the next reboot though. Most configurations for the output are set
with a bit in register 0x00. The general way to change a setting is the following procedure:
-
connect to the MB-4K via Ethernet using a ssh connection or via the RS232 serial port
run the beluga_app that you can find in the /doremi/sbin directory :
-
/doremi/sbin/beluga_app
MB_4K_Manual_000234_v1_3.doc
M4K.OM.000234.DRM
Page 10
Version 1.3
Doremi Labs, Inc Confidential