04. CENTER CASE INSTALLATION
1. Verify if exit device rail length needs be shortened.
If yes, refer to step 6. The exit device requires a
minimum clearance of 1-3/16" between the frame's
door stop and the rail end (with end cover
removed). Otherwise install the exit device on door
as required with a trim or without a trim.
2. If exit device is used with a trim, attach the exit
device and the appropriate trim using instructions
and hardware supplied with the trim and the exit
device.
3. If no trim is used and the exit device is surface
mounted on the door, used supplied mounting
hardware as indicated on pages 2, 3, and 4.
4. Fire exit devices must be installed with
through-bolts when installed without a trim.
1-3/16"
Center Case
Screws
F
E
7/16"
06. CUT DEVICE (IF REQUIRED)
Recommended minimum clearance between
door frame stop and device end (with cap
removed) is 1³⁄16"
Face of door stop
Hinge
Side
DOOR
1³⁄16"
Minimum
Optional
Trim
If a 5/8" diameter hole
is required for the
electrified exit device,
the hole must be
positioned as shown
Center case aligned
with mounting holes.
05. INSTALL BOTTOM LATCH
1. Following the marking of the bottom strike in step 2, prepare the floor
for the appropriate strike and mounting screws
2. If strike is installed on a threshold, provide the required holes and
attach strike with supplied screws.
3. Bottom strike can be installed after bottom latch installation to ensure a
proper alignment.
Pullman Latch
(Defaut)
Round Bottom Latch
Remove
Anti-Rattle Clip
1. With anti-rattle clip removed, tape and mark area being cut.
2. Cut off device and deburr.
NOTE:
Device rail cut must be square, smooth and clean for proper fit
with end cap
6 / 12
N
O
DXAS227
(Default)
E
DXAS225
Cut off line
Cover Plate
(Flush to Push bar)
Tape
E
DXAS224
DXAS226