- ページ 8

プロジェクター Canon LV-7220のPDF 機能仕様をオンラインで閲覧またはダウンロードできます。Canon LV-7220 20 ページ。 Expand serial functional specification
Canon LV-7220 にも: 機能仕様 (42 ページ)

Canon LV-7220 機能仕様
Basic Serial Command Functional Specification

6.5. Power On Command

Command
"C00" [CR]
Power On
When already Power On, no need to do.
Detail
When sending this command during processing count down, count down is
terminated.
Acceptable
Response
Unacceptable

6.6. Power Off Command (Quick Power Off)

Command
"C01" [CR]
Power Off (Standby status)
When Power Off with POWER button of the Projector or the Remote control, "Power
Detail
Off" will be displayed. However, as soon as this command is sent, Quick Power Off
is executed
Acceptable
Response
Unacceptable

6.7. Power Off Command

Command
"C02" [CR]
Power Off (Standby status)
When Power Off with POWER button of the Projector or the Remote control, "Power
Detail
Off" will be displayed. However, as soon as this command is sent, Power Off is
executed.
Acceptable
Response
Unacceptable

6.8. Computer 1 Command

Command
"C05" [CR]
Select Computer 1 Input.
Detail
When optional accessory, MCI BOX is installed, select the function.
(Memory Card / Wireless / Wired)
Acceptable
Response
Unacceptable

6.9. Computer 2 Command

Command
"C06" [CR]
Select Computer 2 Input.
Detail
When Computer 2 terminal is set to Monitor Out, the command will not be executed
(the response is "Acceptable" through).
Acceptable
Response
Unacceptable

6.10. Video Command

Command
"C07" [CR]
Detail
Select Video Input
Acceptable
Response
Unacceptable
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
Page 7 of 19