Expand Serial Command Functional Specification

8.11.5. CF_REAR Command

Command
"CF_REAR_%1" [CR]
"ON" ---------- Select Rear
%1
"OFF" --------- Cancel Rear
Set / Cancel Rear. (Only valid when it is in the usual Power On status)
Details
When Rear is On, it will be a mirror-reversed image. This setting status is
stored in EEPROM, hold even if AC Power turning Off and On.
Acceptable
Response
Unacceptable

8.11.6. CF_RCODE Command

Command
"CF_RCODE_%1" [CR]
"001" ---------- Select Code1
"002" ---------- Select Code2
"003" ---------- Select Code3
"004" ---------- Select Code4
%1
"005" ---------- Select Code5
"006" ---------- Select Code6
"007" ---------- Select Code7
"008" ---------- Select Code8
Select Remote Control Code. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable

8.11.7. CF_LANG Command

Command
"CF_LANG_%1" [CR]
"ENG" ---------- Select English
"DEU" ---------- Select German
"FRA" ---------- Select French
"ITA" ------------ Select Italy
"ESP" ----------- Select Spanish
"POR" ---------- Select Portuguese
%1
"NED" ---------- Select Dutch
"SVE" ---------- Select Swedish
"RUS" ---------- Select Russian
"CHI" ----------- Select Chinese
"KOR" ---------- Select Korean
"JPN" ---------- Select Japanese
Set OSD Language. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable

8.11.8. CF_ON-STA Command

Command
""CF_ON-STA_%1" [CR]
"ON" -------- Select Power On Start
%1
"OFF" ------- Cancel Power On Start
Set / Cancel Power ON Start. (Only valid when it is in the usual Power On
Details
status)
turning Off and On.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
This setting status is stored in EEPROM, hold even if AC Power
"000" [CR]
"Error Code" [CR]
Page 24 of 41