- ページ 7

ガレージドアオープナー Dorma ED 250のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Dorma ED 250 12 ページ。 Automatic door system
Dorma ED 250 にも: 取扱説明書 (8 ページ)

Dorma ED 250 取扱説明書
ED 100, ED 250
Activators
Internal and external activators, a Night-/Bank activator and
an intercommunication system may be connected to the door
system. The internal activator is normally installed inside the
building or room while the external activator is installed on
the outside of the building or room. A Night-/Bank activator
is mounted on the outside and often realised as card reader
or key switch.
Manual locking device
When the door is locked by hand:
• The operator must be adjusted to OFF in order to avoid
damage to the door system.
• If a lock switch is installed, the operator will be
switched off automatically.
DORMA recommends installing a lock switch.
Safety equipment
The required safety equipment in accordance with
the latest state of the common and country-specific
standards, laws, codes and regulations has to be
installed before the system is mounted.
The ED 100 and ED 250 operators may be used in a low-
energy-mode and a full-energy-mode.
Low-Energy-Mode
The low driving speed of the door avoids dangers resulting
from the automatic movement of the door as far as possible.
The door opens at an extremely low speed and thus offers a
high safety level.

7. Malfunctions

Malfunctions may have different reasons.
Ambient conditions often cause malfunctions, thus the
operator tries to analyse these conditions and to respond
correspondingly. In this case the operator interrupts its
currently adjusted function and restarts following a certain
standby-time or when a new pulse has been triggered. In
case this fails, the automatic function of the operator is
switched off and the system displays an error message.
A red LED at the program switch indicates the malfunction.
The LED either blinks or shows a continuous light and
thereby indicates that the malfunction has to be removed by
DORMA Service.
Self-help in case of malfunctions
You have the following options to reset error messages:
1.
Set program switch to OFF or reset the system with
the aid of the RESET key on the user interface while
the cover is open.
2.
Mains reset: Set mains switch to OFF; then wait for 10
seconds and set it back to ON position.
Always analyse and remove the cause for the malfunction
before you acknowledge the respective error message.
Full-Energy-Mode
Due to the high driving speed of the door, the swing path has
to be protected with the aid of sensors.
Safety sensors that are mounted to the door leaf monitor the
swing path and thus avoids that people are hit by the door as
far as possible.
Safety sensors on hinge side
In case an obstruction is detected within the detection range
of the safety sensors:
• The door stops during its opening cycle
• The door remains closed (does not perform an opening
cycle) if the door is in "closed" position.
The operator will resume standard operation as soon as the
detection range is no longer obstructed.
Safety sensors on opposite hinge side
In case an obstruction is detected within the detection range
of the safety sensors:
• The door will reverse during the closing cycle
• The door will remain open.
The operator will resume standard operation as soon as the
detection range is no longer obstructed.
Maintenance interval indicator
In case you have installed the internal 4-position program
switch, you will have a maintenance interval indicator. A
yellow LED informs you that the system has to be serviced.
DORMA Service may adjust the maintenance interval
indicators.
The following table is designed for you assistance.
Please check the following questions in case the door still
does not close or open:
• Is the power supply available?
• Is the mains switch adjusted to ON?
• Is the door freely movable?
• Is the door locked manually? Has the lock switch been
activated?
• Is the program switch properly adjusted (correct
position)?
• Is the swing path unobstructed?
• Has the hold-open device been triggered?
In case you have checked all the above-mentioned questions
and the system still does not work, please contact DORMA
Service to remove the malfunction.
DORMA
7