Ventilator installation
According to the site to choose suitable installation, Air inlet/outlet from back or from the side
Back installation
1. Choose the suitable location on wall, mark the
OA inlet and EA outlet location, also mark the 5
fixing holes of the installation panel on the wall
Attention; Ventilator bottom to the floor around 1.5 meters
Ventilator left and right side to the wall not less than 0.3 meter
2. To drill 2 holes on wall for fresh air inlet and exhaust air outlet, recommended size is
diameter 100mm, The 2 holes should face downward toward the outside to
prevent any rain water ingress. Recommended size for the 5 fixing holes is
φ6x70mm, and input the 5 plastic bolt Jacket into the holes
Attention: The OA inlet and EA outlet holes size is according to the ICERA Hepa W accessories
(PVC pipes).
3. Connect the flange to the installation panel by M3X12 bolt and nut
4. According to the wall thickness, cut the suitable length of the PVC pipes, connect the PVC pipes to the flanges and
also the OA inlet grille and EA outlet grille , please pay attention that the eave of the cover is at the top