Configure Via Control Unit
17. CONFIGURE VIA CONTROL UNIT
LOCK MOTOR CABLE (2-PIN)
DIP SWITCHES
DIP SWITCH "A" - UNIT ID
Switches A1 and A2 are used to set the Unit ID of the lock (1 or 2). Switches A3 and A4 are not
used and should be in the UP (OFF) position.
Slide switch A1 to DOWN (ON) to set the Unit ID to 1 (default):
Slide switch A2 to DOWN (ON) to set the Unit ID to 2:
DIP SWITCH "B" - NET ID
Switches B1-B6 are used to set a Network ID which can be from 1 to 63 and must match the Net-
work ID of the Via Hub with which this lock will communicate. Do not duplicate Via Hub Network
IDs unless they are well out of the range of each other (500 feet should be safe). This switch is ori-
ented vertically. Set the Network ID according to the table below:
LED CABLE (4-PIN)
FROM READER
FROM LOCK
Figure 4: Configure Via Control Unit
Installation Manual
CONNECTION
STATUS LED
(BLUE)
cansec.com
E
ON
PROG
Via Wireless Lock
UNIT ID
READER
A
ON
NET ID
B
ON
C
RST
OPTIONS
ON
D
-
+
ON
ON
ON
July 2018 • Rev. 1.3
READER CABLE
FROM READER
DOOR CONTACT CABLE
REX CABLE FROM LOCK