- ページ 2
スイッチ DOTECH DPX100-150-00-KGFのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。DOTECH DPX100-150-00-KGF 4 ページ。 Digital pressure switch
2.
INSTALLATION
:
DIMENSIONS AND MOUNTING(unit: mm)
:
WIRING DIAGRAM
3.
USER INTERFACES
:
DISPLAY AND CONTROLS
: TRIP / ALARM MESSAGE
No
Menu
1
Internal Parameter Error
2
Pressure Sensor Open
3
Pressure Sensor Short
※ When it alarms, it beeps and all the outputs are cut off. To stop the beep, press the reset.
Code
Description / Instructions
5 Y 5
Change any parameters and turn off. Then restart.
O PN
Please check a pressure sensor because it is open
5 HT
Please check a pressure sensor because it is short
※ Please install a siphon tube to protect from pulsating pressure and high temperature contact.
No
Connection
Description
1
L1
100–240Vac, 50/60Hz Power Input
2
L2
3
Step 1 Normal open signal
4
n1
common signal
5
Step 1 Normal close signal
6
Step 2 Normal open signal
7
n2
common signal
8
Step 2 Normal close signal
9
Step 3 Normal open signal
n3
10
common signal
11
TRX + signal
RS485
12
TRX - signal
Description
n1
Step1 ON/OFF of Output
LED
n2
Step2 ON/OFF of Output
n3
Step3 ON/OFF of Output
Parameter Settings /
Manual Reset(if pressed twice quickly)
Increase or Move Up
Button
Decrease or Move Down
Select & Save / Display of Saturated Temperature
Setup values will be initialized
if pushing PRG button and ▼button for 10 seconds.
-2-
Response at Detection
Reset Type
Immediate Stop
Automatic Reset
Immediate Stop
Automatic Reset
Immediate Stop
Automatic Reset
DPX100 R20141014