7. Proceed to the lower chalk lines previously snapped
on the roof for the strap hold-down brackets. Mark a
hole 2" to the side of the first panel and continue
marking holes on the chalk line centered exactly
between the absorber surfaces until you reach the last
collector. Mark the last hole the same 2" to the side of
the last panel. Drill a pilot hole and apply roof sealant
at each of these locations. Bolt the strap hold-down
brackets on the roof. Refer to Figure 9. It is OK to
step on the collectors as long as you stay one foot
away from the top and bottom headers.
8. Slip one end of a hold-down strap through the slots
in the strap hold-down bracket at the end of the row.
Pull about 9" of the strap through and slip the loose
end of the strap through the slot closer to the collector
and pull it tight and tie a double knot. Refer to Figure
10.
9. Bring the remaining strap end across the panel face,
passing through both slots in the bracket located on
the other side of the panels. Pull the straps taut against
the face of the panel. Repeat this procedure for the
remaining hold-down strap. Refer to Figure 11.
10. Secure opposite end of strap as shown in Figure
10
Repeat this procedure for the center and the bottom
straps.
11. Install the vacuum relief valve in the outlet header
of each row. This will be located at the opposite end
of the row that is connected to the collector outlet
pipe. Refer to Figures 4 and 12.
12. Install an end cap in the inlet header of each row,
opposite the end that is connected to the collector inlet
pipe. Refer to Figures 4 through 12.
13.
INSPECT THE INSTALLATION AND CHECK
ALL CLAMPS FOR PROPER POSITION AND
TIGHTNESS.
14.
FOR HURRICANE OR HIGH WIND AREAS,
USE HURRICANE PANEL HOLD-DOWN KIT, Part
No.
18006.
CONTACT
INSTALLATION INSTRUCTIONS.
Refer to the 'System Diagram' Figure 12, throughout
this section. The most common piping configurations
use a pressure filter. The pump draws the water from
the skimmer and/or a main drain, forcing it through
the filter and sending back to the pool through the
return lines.
If a fuel-fired heater is installed, it is located between
the filter and the return line to the pool. The pipes to
and from the solar collectors are connected to the
return line to the pool before the water enters the fuel-
fired heater, if one is used.
Whenever there is more than 40 gpm required flow
rate to the collectors or more than 100 feet of piping
used in a system, install 2" piping to and from the
panels. Piping to and from the collectors shouldbe the
same type of plastic piping and fittings approved for
use with summing pool filters and pumps. It is
recommended to always user Schedule 40 PVC pipe
and fittings.
FACTOR