DEVICE SETUP
OPERATING KEYS
Click
Change selected fi eld
Change selected fi eld value
value
Click
Go to next window
Back to initial entry fi eld
2 sec
ENTERS INTO SET UP MODE
(Push together for 2 seconds)
SETUP SEQUENCE
PAGE
PARAMETERS
PASSWORD REQUEST
RS485
RS485 Address
Rate
Data Bit
Parity
Stop Bit
ADDR 027
COM
S.T.
NETWORK
Type (note n.1)
Export
CT
VT
TYPE
EXPORT NO
CT
VT
AVG-MD TIME (note n.2)
POWERS
CURRENTS
POWERS
CURRENTS 08
ALARM 1 / A (note n.11)
MODE (note n.3)
TYPE (note n.4)
MEAS (note n.5)
THRE (note n.5)
MODE
TYPE
MEAS
THRE
ALARM 1 / B
HYST
DELAY
AVG (note n.6)
OUT (note n.7)
HYST
DELAY
AVG
OUT
ALARM 2 / A (note n.11)
MODE (note n.3)
TYPE (note n.4)
MEAS (note n.5)
THRE (note n.5)
ALARM 2 / B
HYST
DELAY
AVG (note n.6)
OUT (note n.7)
ALARM 3 / A (note n.11)
MODE (note n.3)
TYPE (note n.4)
MEAS (note n.5)
THRE (note n.5)
ALARM 3 / B
HYST
DELAY
AVG (note n.6)
OUT (note n.7)
ALARM 4 / A (note n.11)
MODE (note n.3)
TYPE (note n.4)
MEAS (note n.5)
THRE (note n.5)
ALARM 4 / B
HYST
DELAY
AVG (note n.6)
OUT (note n.7)
Go to next fi eld
Exits setup
VALUES AVAILABLE
0000 ... 9999
1 ... 247
2400, 4800, 9600, 19200, 38400
7 or 8
N = no parity, E =even parity, O = odd parity
1 or 2
RS-485
38400-8-N-2
100
3PH-3W-2CT, 3PH-4W, 2PH-2W, 1PH-2W
NO, YES
10000/1 or 5
400000/300
NETWORK
3PH-4W
00005/5
000001/001
1...60 (minutes)
1...60 (minutes)
AVG-MD TIME
15
Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL
MAX, MIN
Controlled measure. See table n.1 for register
selection
Threshold value
ALARM 1/A
NORMAL
MIN
200
000.00
1...100 (%)
1...99 (seconds)
1...99 (seconds)
Normal, Hold, Pulse-L, Pulse-S
ALARM 1/B
01
01 S/01 S
01
NORMAL
Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL
MAX, MIN
Controlled measure. See table n.1 for register
selection
Threshold value
1...100 (%)
1...99 (seconds)
1...99 (seconds)
Normal, Hold, Pulse-L, Pulse-S
Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL
MAX, MIN
Controlled measure. See table n.1 for register
selection
Threshold value
1...100 (%)
1...99 (seconds)
1...99 (seconds)
Normal, Hold, Pulse-L, Pulse-S
Normal, 1-OF-3, 3-OF-3, DERIV, UNBAL
MAX, MIN
Controlled measure. See table n.1 for register
selection
Threshold value
1...100 (%)
1...99 (seconds)
1...99 (seconds)
Normal, Hold, Pulse-L, Pulse-S
DISPLAY
CONTRAST
DIGITAL OUT 1 (note n.8)
MODE
POLARITY
PULSE OUT 1
MEAS (note n.9)
PRIMARY (note n.10)
WEIGHT
WIDTH
DEFAULT
0000
DIGITAL OUT 2 (note n.8)
MODE
27
POLARITY
38400
PULSE OUT 2
8
N
MEAS (note n.9)
2
PRIMARY (note n.10)
WEIGHT
WIDTH
CLEAR TOTAL COUNTERS
CLEAR PARTIAL COUNTERS
CLEAR MIN-MAX
CLEAR MAX DEMAND
3PH-4W
RESTORE FACTORY SETTINGS
NO
ENTER NEW PASSWORD
5/5
1/1
EXIT SETUP
(push for 2 seconds)
15
TABLE n.1 (ModBus Registers for alarm confi guration)
8
REGISTER DESCRIPTION
200
Phase to Neutral Voltage, THD
202
Phase to Neutral Voltage, THD
204
Phase to Neutral Voltage, THD
206
Phase to Phase Voltage, THD
208
Phase to Phase Voltage, THD
NORMAL
210
Phase to Phase Voltage, THD
MIN
212
Phase Current, THD
200
214
Phase Current, THD
216
Phase Current, THD
0
218
Frequency of U1N
220
Phase to Neutral Voltage, RMS Amplitude
222
Phase to Neutral Voltage, RMS Amplitude
224
Phase to Neutral Voltage, RMS Amplitude
226
Phase to Phase Voltage, RMS Amplitude
228
Phase to Phase Voltage, RMS Amplitude
230
Phase to Phase Voltage, RMS Amplitude
232
Phase Current, RMS Amplitude
1
234
Phase Current, RMS Amplitude
1
236
Phase Current, RMS Amplitude
1
238
Neutral Current, RMS Amplitude
NORMAL
240
Phase Active Power ( Imp/ Exp)
242
Phase Active Power ( Imp/ Exp)
244
Phase Active Power ( Imp/ Exp)
246
Phase Reactive Power ( Imp/ Exp)
248
Phase Reactive Power ( Imp/ Exp)
250
Phase Reactive Power ( Imp/ Exp)
252
Phase Apparent Power
254
Phase Apparent Power
NORMAL
256
Phase Apparent Power
MIN
258
Phase Power Factor ( Imp/ Exp)
200
260
Phase Power Factor ( Imp/ Exp)
0
262
Phase Power Factor ( Imp/ Exp)
264
Phase to Neutral Voltage, Mean THD
1
266
Phase to Phase Voltage, Mean THD
1
268
Phase Current, Mean THD
1
270
Phase to Neutral Voltage, Mean RMS Amplitude
NORMAL
272
Phase to Phase Voltage, Mean RMS Amplitude
274
Three phase current, RMS Amplitude
NORMAL
276
Total active power ( Imp/ Exp)
MIN
278
Total reactive power ( Imp/ Exp)
200
280
Total apparent power
0
282
Total power factor ( Imp/ Exp)
332
Phase Current, RMS Amplitude, AVG
1
334
Phase Current, RMS Amplitude, AVG
1
336
Phase Current, RMS Amplitude, AVG
1
344
Total imported active power, AVG
NORMAL
346
Total imported inductive power, AVG
348
Total imported capacitive power, AVG
NORMAL
350
Total imported apparent power, AVG
MIN
352
Total exported active power, AVG
200
354
Total exported inductive power, AVG
0
356
Total exported capacitive power, AVG
358
Total exported apparent power, AVG
1
376
External Pulse Counter, With Weight, Total counter
1
or Tariff T1
1
384
External Pulse Counter, With Weight, Partial
NORMAL
Counter or Tariff T2
20 - 45
PULSE, ALARM, REMOTE
NO, NC
DIGITAL OUT 1
MODE
PULSE
POLATITY
NO
P-IMP, QL-IMP, QC-IMP, S-IMP, P-EXP,
QL-EXP, QC-EXP, S-EXP
YES, NO
1...100000000 (Wh/100)
50ms...1S
PULSE OUT 1
MEAS
P-IMP
PRIMARY
YES
WEIGHT
100.00k
WIDTH
0500
PULSE, ALARM, REMOTE
NO, NC
P-IMP, QL-IMP, QC-IMP, S-IMP, P-EXP,
QL-EXP, QC-EXP, S-EXP
YES, NO
1...100000000 (Wh/100)
50ms...1S
NO, YES
NO, YES
NO, YES
NO, YES
NO, YES
0000 ... 9999
SYMBOL
THD U1N
THD U2N
THD U3N
THD U12
THD U23
THD U31
THD I1
THD I2
THD I3
f
U1N
U2N
U3N
U12
U23
U31
I1
I2
I3
IN
P1
P2
P3
Q1
Q2
Q3
S1
S2
S3
PF1
PF2
PF3
THD Ul
THD UD
THD I
Ul
UD
I
PS
QS
SS
PFS
I1 AVG
I2 AVG
I3 AVG
P Imp AVG
Qind Imp AVG [var]
Qcap Imp AVG [var]
S Imp AVG
P Exp AVG
Qind Exp AVG [var]
Qcap Exp AVG [var]
S Exp AVG
CNT1 S
CNT1 P
28
PULSE
NO
P-IMP
YES
100000
500
PULSE
NO
QL-IMP
YES
100000
500
NO
NO
NO
NO
NO
0000
UNITS
[%]
[%]
[%]
[%]
[%]
[%]
[%]
[%]
[%]
[Hz]
[V]
[V]
[V]
[V]
[V]
[V]
[A]
[A]
[A]
[A]
[W]
[W]
[W]
[var]
[var]
[var]
[VA]
[VA]
[VA]
[-]
[-]
[-]
[%]
[%]
[%]
[V]
[V]
[A]
[W]
[var]
[VA]
[-]
[A]
[A]
[A]
[W]
[VA]
[W]
[VA]