Installation position: 2-dimensional
3.2.2
Inclination sensor GIM500R can be installed both in horizontal and vertical position (according to the default
settings).
Horizontal installation
The 2-dimensional inclination sensor (housing in horizontal position) must be installed with the base plate
aligned parallel to the horizontal line. The sensor can be inclined both towards the X and Y direction at the
same time. By default, the sensor measures within the configured range, e.g. ±30° in both directions. Zero
crossing is exactly the horizontal line.
Vertical installation
The 2-dimensional inclination sensor (housing in vertical position) must be installed with the base plate
vertically aligned. The sensor can be inclined both towards the X and Y direction at the same time, for each a
separate measured value is supplied. By default, the sensor measures within the configured range, e.g. ±30°
in both directions. Zero crossing is exactly in the vertical line.