General notes
Rules for proper usage
Set-up
Installation
Caution
Laser safety
Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3., as described
in Laser Notice No. 56, dated May 8, 2019
The laser diode installed in the OADM emits visible red laser lights. This laser belongs to the Class 2 laser
standard specified by the IEC 60825-1
Max. average output power < 1 mW
Laser radiation, do not stare into beam
To avoid uncontrolled laser exposure we recommended stopping the beam with a matte object.
For laser safety reasons, the voltage supply of the sensors must be turned off when the whole system or
the machine is turned off.
CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein
may result in hazardous radiation exposure.
BA_OADM20x5.doc ANW_81253059
03.07.2017
This product is a precision device which has been designed for the
detection of objects and parts. It generates and provides measured
values issued as electrical signals for following systems. Unless this
product has not been specifically marked it may not be used in
hazardous areas.
Installation, mounting and adjustment of this product may only be
executed by skilled employees.
Only mounting devices and accessories specifically provided for this
product may be used for installation.
Unused outputs may not be connected. Unused strands of hard-
wired sensors must be isolated. Do not exceed the maximum
permissible bending radius of the cable. Before connecting the
product electrically the system must be powered down. Where
screened cables are mandatory, they have to be used in order to
assure EMI protection. When assembling connectors and screened
cables at customer site the screen of the cable must be linked to the
connector housing via a large contact area.
Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation
exposure.