9 Grounding concept

For maximum EMC protection and reliable application, use a shielded cable. Also, the sensor has to be
grounded.
We recommend the grounding concept as shown in the picture. Ground the sensor with a toothed washer
between the screw head and the sensor.
● = electrical connection
OADM
If you prefer another grounding concept please contact your Baumer electric sales staff.

10 Service notes

The OADM requires no maintenance apart from keeping the front windows clean. Dust or fingerprints can
impair the sensor function. It is normally sufficient to wipe the windows dry with a clean (!), soft cloth. Alcohol
or soapy water may be used for heavy soiling.

11 Accessories

Connecting cable, straight
Protective cover
BA_OADM20x5.doc ANW_81253059
03.07.2017
Power-supply
A/D Converter
ESG 34CH0200G, 5 pins, length 2 m, shielded
ESG 34CH0500G, 5 pins, length 5 m, shielded
part no. 10156878, material is acrylic glass (PMMA)
The protection cover can be easily mounted on the sensor's face. It protects
the glass front cover against welding splashes.