Radar Sensoren
Radar sensors
Détecteurs à radar
R600V.DAE0-11188367
Radarsensor für Boden- und Pfl anzen-
abstand (für allgemeine Anwendungen)
Radar sensor for ground & crop
distance (for general applications)
Détecteurs radar approprié à la mesure
de la distance du sol et des plantes
(pour utilisation général)
Í?+2scÂÂ*Â@Î
11188367
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/4
Abmessungen
Dimensions
82
62
97
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Erfassungsbereich Sd
0,3 ... 5 m
Öff nungswinkel
6° (3dB)
Betriebsspannungsbereich
9 ... 32 VDC
+Vs
Stromaufnahme max.
160 mA
(ohne Last)
Ausgangsschaltung
CAN (5V)
logische Schnittstelle
CAN SAE J1939
Baud Rate
250 kBaud
kurzschlussfest
ja
verpolungsfest
ja, Vs zu GND
Arbeitstemperatur
-40 ... +70 °C
Lagertemperatur
-40 ... +85 °C
Schutzart
IP 68/69K
Technische Änderungen vorbehalten
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
NOTICE: Changes or modifi cations made to this equipment not expressly approved by Baumer may void the FCC authorization
to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not in-
stalled and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Radiofrequency radiation exposure Information: This equipment complies with FCC exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your
body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Dimensions
Elektrischer Anschluss
42
(1)
(2)
CAN SAE
(4)
J1939
(3)
32
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
sensing distance Sd
0,3 ... 5 m
aperture angle
6° (3dB)
voltage supply range
9 ... 32 VDC
+Vs
current consumption
160 mA
max. (no load)
output circuit
CAN (5V)
logical interface
CAN SAE J1939
baud rate
250 kBaud
short circuit protection
yes
reverse polarity pro-
yes, Vs to GND
tection
operating temperature
-40 ... +70 °C
storage temperature
-40 ... +85 °C
protection class
IP 68/69K
Tecnical specifi cations subject to change
Canada Compliance Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two condi-
tions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. This equipment complies with IC radiation exposure limits set forth for an un-
controlled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator
and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploita-
tion est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Cet équipement
est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit
être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Ce transmetteur
ne doit pas etre place au meme endroit ou utilise simultanement avec un autre transmetteur ou antenne.
Connection diagram
Schéma de raccordement
+Vs
CAN HI
CAN LO
0 V
Données techniques
Portée de détection Sd
Angle d'ouverture
Plage de tension +Vs
Consommation max. (sans
charge)
circuit de sortie
interface logique
vitesse de transmission
Protégé contre courts-cir-
cuits
Protégé contre inversion
polarité
Température de fonctionne-
ment
Température de stockage
Classe de protection
Sous réserve de modifi cations techniques
2 CAN HI
4 CAN LO
3 GND
1 +Vs
0,3 ... 5 m
6° (3dB)
9 ... 32 VDC
160 mA
CAN (5V)
CAN SAE J1939
250 kBaud
oui
oui, Vs vers GND
-40 ... +70 °C
-40 ... +85 °C
IP 68/69K