Trouble Shooting

Tab 14 Trouble Shooting Overview
Failure
No function, no LED
Function impaired, thick layer of dirt
Mechanical damage to housing
and/or lens
Unexplained
targets
/
distance
measurement in near range
Unexplained
targets
/
distance
measurement in far range
The LED is blinking red (50ms on /
50ms off)
The LED is blinking magenta
The LED is blinking blue for a long
period.
No communication (also magenta
blinking)
No messages are sent
R600V.DAH5_manual_1.5 (EN).docm
Last Update: 03 Jul 20
Action
Check cables, connections, power supply at pins
Clean lens and remove excess water.
Replace part by qualified personnel.
Check free space (or beyond) for non-stationary objects (such as dangling wires,
tubes, water drops on surfaces.
Check for double reflections, and limit measurement range
Hardware fault. Replace part by qualified personnel
CAN bus error. Check Tab 5 for details.
Try a power cycle. If this does not fix the issue peplace part by qualified personnel
Check CAN speed (e.g. 250kbit/sec), check 120Ohm termination,
Check default transmission enable flags (0x0087E38D)
Check if master address has been claimed (when required due to PDU transmis-
sion start mode setting 0x0087E397)
Manual R600V.DAH5 (EN)