- ページ 13

メディア・コンバーター Baumer EAM360R-SのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Baumer EAM360R-S 27 ページ。 Absolute encoder with sae j1939

Baumer EAM360R-S マニュアル

6 Network Management Service

6.1

NAME Field (PGN 60159)

The name field will be sent by the device on every start up as a broadcast message. The name field is used to identify the
device in the network, as well as for the address claiming. The name field can't be configured by the user.
Description
Identifier
PGN60159
EAMxxx
18EEFFACh
6.2

Address Claiming

Every device on the J1939 network needs to observe name field messages on the bus in order to detect, if another device
tries to use the same address as the own device.
When it is detected, that another device using the same address, the own name field is also broadcasted on the bus. The
device with the lower priority (higher Identifier) needs to increment its own address by one and broadcast the name-field
on the bus again. Save and restore commands
Baumer_EAM580_360_EB360_SAE_J1939_MA_EN_Rev0003.0000h_Index0004.docx
05.12.2022
DLC
21 Bit
11 Bit
3 Bit
8
8
A7E7
157h
0h
7h
13/27
Bits of Protocol Data Unit (PDU)
5 Bit
8 Bit
1 Bit
7 Bit
0h
8Eh
0h
4 Bit
3 Bit
1 Bit
0h
0h
5h
1h
Baumer Electric AG
Frauenfeld, Switzerland