- ページ 29
メディア・コンバーター Baumer HOG 100のPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer HOG 100 32 ページ。 Incremental encoder with axial terminal cover
Baumer HOG 100 にも: 取付・取扱説明書 (32 ページ), 取付・取扱説明書 (32 ページ)
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Shaft loading:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB156a - 11069623
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
1024...10000 (As ordered)
90° ±8°
44...56 %
Zero pulse, width 90°
Optical
≤250 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(As ordered)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL approval / E256710
ø105 mm
ø16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
(As ordered)
≤450 N axial; ≤600 N radial
IP66
≤10000 rpm (mechanical)
6 Ncm
320 gcm
Housing: aluminium die-cast
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6:2007, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008, Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
Complies to ISO 12944-5:1998
Protective paint systems (C4)
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Terminal cover
1.5 kg
Baumer_HOG100-R_II_DE-EN (17A1)
2
10
Technical data
26