- ページ 10
メディア・コンバーター Baumer Hubner Berlin PMG10のPDF 取付・取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer Hubner Berlin PMG10 32 ページ。 Absolute encoder
Baumer Hubner Berlin PMG10 にも: 取付・取扱説明書 (32 ページ), 取扱説明書 (44 ページ)
MOUNTING / EURO FLANGE B10
4.
MOUNTING
4.1
EURO flange B10
4.1.1
Mounting the spring disk coupling to the device
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
14, available as accessory� When other couplings are used pay attention to
manufacturer's notes�
4.1.2
Mounting to the drive shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error�
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
10/32
2�5 mm
7
M
= 1 Nm
t
9
10 mm
MB261EN - 11196414, 21A1, Baumer_PMG10-Inc_EN_202103_MI_11196414
8
section 4.3,