- ページ 15

メディア・コンバーター Baumer HUBNER BERLIN PROFI NET microGen HMG10PのPDF 取付・取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer HUBNER BERLIN PROFI NET microGen HMG10P 32 ページ。 Incremental encoder with magnetic sensing
Baumer HUBNER BERLIN PROFI NET microGen HMG10P にも: 取付・取扱説明書 (40 ページ), 取扱説明書 (44 ページ)

Baumer HUBNER BERLIN PROFI NET microGen HMG10P 取付・取扱説明書
4.5
How to prevent measurement errors
To ensure that the device operates correctly, it is necessary to mount it accurately as de-
scribed in section 4�1 to 4�4, which includes correct mounting of the torque arm�
The radial runout of the drive shaft should not exceed 0�2 mm (0�03 mm recommended),
to prevent an angle error�
An angle error may be reduced by increasing the length of L1
L2 of the torque arm, see below, is at least equal to L1
The angle error Δρ
Δρ
= ±90°/π · R/L1
mech
with R: Radial runout in mm
L1:
Example of calculation:
For R = 0.06 mm and L1 = 69.5 mm the resulting angle error Δρ
i
For more information, call the telephone hotline at +49 (0)30 69003-111�
For this different support plates for the torque arm are available on request�
1)
If L2 < L1, L2 must be used in the calculation formula�
2)
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
can be calculated as follows:
mech
Distance of the torque arm to the center point of the device in mm
MOUNTING / HOW TO PREVENT MEASUREMENT ERRORS
L1
� Make sure that the length
1)
2)
equals ±0�025°�
mech
12/27