- ページ 24

メディア・コンバーター Baumer Hubner EtherNet/IP HMG10のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer Hubner EtherNet/IP HMG10 44 ページ。

Baumer Hubner EtherNet/IP HMG10 取扱説明書
5
|
Installation
5.7

Avoiding and calculating angular errors

INFO
For further information, please call the telephone hotline at +49 (0)30 69003-111.
Instruction:
a) Make sure that concentricity errors of the drive shaft do not exceed 0.2 mm (0.03 mm rec-
ommended) to prevent angular errors.
b) Limit such angular errors by increased gap L1. For doing so, various torque plates for are
available on request.
c) Note that length L2 of the torque arm should be ≥ L1. Where not possible, consider L2.
d) To calculate angular errors Δp
tical gap of torque arm towards the device center in mm):
Δp
mech
Calculation example:
With R= 0.06 mm and L1 = 69.5 mm, the angular error Δp
24
 = ±90°/π × R/L1
Operating Manual
L1
proceed as follows ( R = runout error in mm and L1 = ver-
mech
HMG10 & HMG10P EtherNet/IP | V1, T1
Baumer Hübner
is ±0.025°.
mech