- ページ 10
メディア・コンバーター Baumer PMG 10 Profibus DPのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer PMG 10 Profibus DP 32 ページ。 Absolute encoder with magnetic sensing
MOUNTING / MOUNTING WITH EURO FLANGE B10
4.
MOUNTING
4.1
Mounting with EURO flange B10
4.1.1
Mounting the spring disk coupling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
11, available as accessory. When other couplings are used pay attention to
manufacturer's notes.
2�5 mm
7
M
= 100 Ncm
t
4.1.2
Mounting to drive shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error.
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder.
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water.
7/29
9
8
10 mm
MB247EN - 11171697, 17A2, Baumer_PMG10-ProfibusDP_II_EN